Item<br />

2. Indoor fan<br />

motor control<br />

COOL ON<br />

Operation flow and applicable data, etc.<br />

<br />

(This operation controls the fan speed at indoor unit side.)<br />

The indoor fan (cross flow fan) is operated by the phasecontrol<br />

induction motor. The fan rotates in 5 stages in<br />

<strong>MANUAL</strong> mode, and in 5 stages in AUTO mode, respectively.<br />

(Table 1)<br />

Description<br />

* Symbols<br />

UH : Ultra High<br />

H : High<br />

M+ : Medium+<br />

M : Medium<br />

L+ : Low+<br />

L : Low<br />

L- : Low–<br />

UL : Ultra Low<br />

SUL : Super Ultra Low<br />

Fan speed setup<br />

Ta<br />

[˚C]<br />

+2.5<br />

+2.0<br />

+1.5<br />

+1.0<br />

AUTO<br />

a<br />

b<br />

c<br />

<strong>MANUAL</strong><br />

(Fig. 1)<br />

Indication<br />

Fan speed<br />

L<br />

W6<br />

L+<br />

(L + M) / 2<br />

M<br />

W9<br />

M+<br />

(M + H) / 2<br />

H<br />

WC<br />

(Fig. 2)<br />

Air volume AUTO<br />

M+(WB)<br />

*3 *3 : Fan speed = (M + –L) x 3/4 + L<br />

*4 *4 : Fan speed = (M + –L) x 2/4 + L<br />

*5 *5 : Fan speed = (M + –L) x 1/4 + L<br />

* The fan speed broadly varies due<br />

to position of the louver, etc.<br />

The described value indicates one<br />

under condition of inclining<br />

downward blowing.<br />

1) When setting the fan speed to L,<br />

L+, M, M+ or H on the remote<br />

controller, the operation is<br />

performed with the constant<br />

speed shown in Fig. 1.<br />

2) When setting the fan speed to<br />

AUTO on the remote controller,<br />

revolution of the fan motor is<br />

controlled to the fan speed level<br />

shown in Fig. 2 and Table 1<br />

according to the setup temperature,<br />

room temperature, and heat<br />

exchanger temperature.<br />

+0.5<br />

Tsc<br />

d<br />

e<br />

L(W6)<br />

(Linear approximation<br />

from M+ and L)<br />

(Table 1) Indoor fan air flow rate<br />

Fan speed<br />

level<br />

COOL<br />

FAN<br />

ONLY<br />

HEAT<br />

DRY<br />

RAS-B10GKVP-E<br />

RAS-M10GKCVP-E<br />

Fan speed<br />

(rpm)<br />

Air flow rate<br />

(m 3 /h)<br />

RAS-B13GKVP-E<br />

RAS-M13GKCVP-E<br />

Fan speed<br />

(rpm)<br />

Air flow rate<br />

(m 3 /h)<br />

RAS-B16GKVP-E<br />

RAS-M16GKCVP-E<br />

Fan speed<br />

(rpm)<br />

Air flow rate<br />

(m 3 /h)<br />

WF<br />

WE<br />

WD<br />

WC<br />

WB<br />

WA<br />

W9<br />

W8<br />

W7<br />

W6<br />

W5<br />

W4<br />

W3<br />

W2<br />

W1<br />

UH<br />

H<br />

M+<br />

M<br />

L+<br />

L<br />

L–<br />

UL<br />

SUL<br />

UH<br />

H<br />

M+<br />

M<br />

L+<br />

L<br />

L–<br />

UL<br />

SUL<br />

L+<br />

L<br />

L–<br />

UL<br />

SUL<br />

1630 684<br />

1480 609<br />

1400 569<br />

1350 544<br />

1200 468<br />

1110 423<br />

980 358<br />

910 323<br />

900 318<br />

890 313<br />

880 308<br />

730 232<br />

580 157<br />

430 82<br />

400 67<br />

1650 694<br />

1530 634<br />

1440 589<br />

1390 564<br />

1240 488<br />

1150 443<br />

1010 373<br />

910 323<br />

900 318<br />

890 313<br />

880 308<br />

730 232<br />

580 157<br />

430 82<br />

400 67<br />

1650 694<br />

1580 659<br />

1550 644<br />

1530 634<br />

1380 559<br />

1230 483<br />

1080 408<br />

970 353<br />

960 348<br />

950 343<br />

940 338<br />

790 263<br />

640 187<br />

490 112<br />

400 67<br />