Item<br />
2. Indoor fan<br />
motor control<br />
COOL ON<br />
Operation flow and applicable data, etc.<br />
<br />
(This operation controls the fan speed at indoor unit side.)<br />
The indoor fan (cross flow fan) is operated by the phasecontrol<br />
induction motor. The fan rotates in 5 stages in<br />
<strong>MANUAL</strong> mode, and in 5 stages in AUTO mode, respectively.<br />
(Table 1)<br />
Description<br />
* Symbols<br />
UH : Ultra High<br />
H : High<br />
M+ : Medium+<br />
M : Medium<br />
L+ : Low+<br />
L : Low<br />
L- : Low–<br />
UL : Ultra Low<br />
SUL : Super Ultra Low<br />
Fan speed setup<br />
Ta<br />
[˚C]<br />
+2.5<br />
+2.0<br />
+1.5<br />
+1.0<br />
AUTO<br />
a<br />
b<br />
c<br />
<strong>MANUAL</strong><br />
(Fig. 1)<br />
Indication<br />
Fan speed<br />
L<br />
W6<br />
L+<br />
(L + M) / 2<br />
M<br />
W9<br />
M+<br />
(M + H) / 2<br />
H<br />
WC<br />
(Fig. 2)<br />
Air volume AUTO<br />
M+(WB)<br />
*3 *3 : Fan speed = (M + –L) x 3/4 + L<br />
*4 *4 : Fan speed = (M + –L) x 2/4 + L<br />
*5 *5 : Fan speed = (M + –L) x 1/4 + L<br />
* The fan speed broadly varies due<br />
to position of the louver, etc.<br />
The described value indicates one<br />
under condition of inclining<br />
downward blowing.<br />
1) When setting the fan speed to L,<br />
L+, M, M+ or H on the remote<br />
controller, the operation is<br />
performed with the constant<br />
speed shown in Fig. 1.<br />
2) When setting the fan speed to<br />
AUTO on the remote controller,<br />
revolution of the fan motor is<br />
controlled to the fan speed level<br />
shown in Fig. 2 and Table 1<br />
according to the setup temperature,<br />
room temperature, and heat<br />
exchanger temperature.<br />
+0.5<br />
Tsc<br />
d<br />
e<br />
L(W6)<br />
(Linear approximation<br />
from M+ and L)<br />
(Table 1) Indoor fan air flow rate<br />
Fan speed<br />
level<br />
COOL<br />
FAN<br />
ONLY<br />
HEAT<br />
DRY<br />
RAS-B10GKVP-E<br />
RAS-M10GKCVP-E<br />
Fan speed<br />
(rpm)<br />
Air flow rate<br />
(m 3 /h)<br />
RAS-B13GKVP-E<br />
RAS-M13GKCVP-E<br />
Fan speed<br />
(rpm)<br />
Air flow rate<br />
(m 3 /h)<br />
RAS-B16GKVP-E<br />
RAS-M16GKCVP-E<br />
Fan speed<br />
(rpm)<br />
Air flow rate<br />
(m 3 /h)<br />
WF<br />
WE<br />
WD<br />
WC<br />
WB<br />
WA<br />
W9<br />
W8<br />
W7<br />
W6<br />
W5<br />
W4<br />
W3<br />
W2<br />
W1<br />
UH<br />
H<br />
M+<br />
M<br />
L+<br />
L<br />
L–<br />
UL<br />
SUL<br />
UH<br />
H<br />
M+<br />
M<br />
L+<br />
L<br />
L–<br />
UL<br />
SUL<br />
L+<br />
L<br />
L–<br />
UL<br />
SUL<br />
1630 684<br />
1480 609<br />
1400 569<br />
1350 544<br />
1200 468<br />
1110 423<br />
980 358<br />
910 323<br />
900 318<br />
890 313<br />
880 308<br />
730 232<br />
580 157<br />
430 82<br />
400 67<br />
1650 694<br />
1530 634<br />
1440 589<br />
1390 564<br />
1240 488<br />
1150 443<br />
1010 373<br />
910 323<br />
900 318<br />
890 313<br />
880 308<br />
730 232<br />
580 157<br />
430 82<br />
400 67<br />
1650 694<br />
1580 659<br />
1550 644<br />
1530 634<br />
1380 559<br />
1230 483<br />
1080 408<br />
970 353<br />
960 348<br />
950 343<br />
940 338<br />
790 263<br />
640 187<br />
490 112<br />
400 67<br />