8. CONTROL BLOCK DIAGRAM<br />

8-1. Indoor Unit<br />

RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E<br />

Heat Exchanger Sensor (Tc)<br />

Room Temperature Sensor (Ta)<br />

Infrared Rays Signal Receiver<br />

and Indication<br />

Initializing Circuit<br />

Clock Frequency<br />

Oscillator Circuit<br />

Functions<br />

M.C.U.<br />

• Cold draft preventing Function<br />

• 3-minute Delay at Restart for Compressor<br />

• Fan Motor Starting Control<br />

• Processing<br />

(Temperature Processing)<br />

• Timer<br />

• Serial Signal Communication<br />

• Clean Function<br />

Indoor Unit Control Unit<br />

Louver Motor<br />

Drive Control<br />

Indoor Fan<br />

Motor Control<br />

Louver<br />

Motor<br />

Indoor<br />

Fan Motor<br />

Power Supply<br />

Circuit<br />

Air purifier<br />

unit<br />

Converter<br />

(D.C circuit)<br />

Micro Switch<br />

Noise Filter<br />

Serial Signal Transmitter/Receiver<br />

From Outdoor Unit<br />

220-240V ~50Hz<br />

220V ~60Hz<br />

Serial Signal Communication<br />

(Operation Command and Information)<br />

REMOTE CONTROLLER<br />

Remote Controller<br />

Operation (START/STOP)<br />

Operation Mode Selection<br />

AUTO, COOL, DRY, HEAT<br />

Thermo. Setting<br />

Fan Speed Selection<br />

ON TIMER Setting<br />

OFF TIMER Setting<br />

Louver AUTO Swing<br />

Louver Direction Setting<br />

ECO<br />

Hi-POWER<br />

Air Purifier<br />

SLEEP<br />

Infrared Rays, 36.7kHz<br />

– 45 –