11.07.2015 Views

Glenbrook Sation REF (pdf 3.15MB) - Transport for NSW - NSW ...

Glenbrook Sation REF (pdf 3.15MB) - Transport for NSW - NSW ...

Glenbrook Sation REF (pdf 3.15MB) - Transport for NSW - NSW ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Review of Environmental Factors<strong>Glenbrook</strong> commuter car park and interchange upgradeScenario Equipment 1 No ofitems inone 15minperiod7 ‐ Installation of permanentperimeter fencing8 ‐ Line‐markings and signposting9 – Landscaping10 ‐ Optus night works11 ‐ Signals works during possession12 ‐ Installation of power polesHand Tools 1 94Truck (10 tonne) 1 98Hand Tools 1 94Line Marking Plant 1 98Hand Tools 1 94Truck (10 tonne) 1 98Bobcat 1 104Hand Tools 1 94Hand Tools 1 94Generator (small) 1 95Hand Tools 1 94Generator (small) 1 95Maximum LAeq 2Sound Power Level(dBA)IndividualItemActivity9999105Mobile Crane (25 tonne) 1 99107Piling Rig* 1 108 4Excavator (20 tonne) 1 99Note 1: * denotes “annoying” item of equipment, as defined in the ICNG, and as such includes a +5 dBA penalty to predictions.Note 2: LAeq sound power levels are based on LAmax noise levels published in <strong>Transport</strong> <strong>for</strong> New South Wales Construction NoiseStrategy and the SLR Consulting noise database compiled from on‐site measurements and observations.Note 3:Note 4:Overall Sound Power Level (SWL) assumes a maximum 5 minutes on‐time in any 15‐minute period.Overall SWL assumes a maximum 7.5 minutes on‐time in any 15‐minute period.Workzone A (Commuter Car Park)For the Workzone A works, the noise predictions indicate that worst‐case LAeq(15minute) constructionnoise levels of up to 81 dBA are expected at the nearest residential receiver when scenario 3 works (siteclearing and bulk earthworks) are located adjacent to this receiver. Exceedances of the LAeq(15minute)noise goal of up to 34 dBA are predicted at this receiver location during the daytime period.Should OOHW <strong>for</strong> scenario 12 (installation of power poles) be required, exceedances of theLAeq(15minute) noise goal of up to 30 dBA are predicted at the nearest receiver during the eveningOOHW period.Exceedances of the LAeq(15minute) noise goal of up to 24 dBA are predicted at the nearest receiverlocation during the night‐time OOHW period <strong>for</strong> potential night works (scenarios 10 and 11). The sleepdisturbance screening criterion is also predicted to be exceeded by up to 22 dB <strong>for</strong> these night works.Workzone B (Pedestrian Improvement Works and Mobility Parking Provision)For the Workzone B works, the noise predictions indicate that worst‐case LAeq(15minute) constructionnoise levels of up to 72 dBA are expected at the nearest residential receiver when scenario 6 (pavement9898Ref No: 2260812 45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!