General 07/03 Kollmorgen<br />
1.2 Use as directed<br />
The servo amplifiers are components which are built into electrical equipment or machines, and can<br />
only be commissioned as integral components of such equipment.<br />
The manufacturer of the machine must produce a hazard analysis for the machine and<br />
take appropriate measures to ensure that unforeseen movements do not result in personal<br />
injury or material damage.<br />
Use the servo amplifiers only on the following types of supply:<br />
1 x 115V AC (only <strong>SERVOSTAR</strong> 40xM, unearthed operation is permissible)<br />
3 x 115V AC (only <strong>SERVOSTAR</strong> 40xM, unearthed operation is permissible)<br />
1 x 230V AC (only <strong>SERVOSTAR</strong> 40xM, unearthed operation is permissible)<br />
3 x 230V AC (all types, unearthed operation is permissible)<br />
3 x <strong>400</strong>V AC (only <strong>SERVOSTAR</strong> 44xM, TN-system or TT-system with earthed<br />
neutral point, max. 5000A symmetrical rated current)<br />
If the servo amplifiers are used in residential areas, or in business or commercial premises, then<br />
additional filter measures must be implemented by the user.<br />
The <strong>SERVOSTAR</strong> <strong>400</strong> family of servo amplifiers is only intended to drive specific brushless synchronous<br />
servomotors with closed-loop control of torque, speed and/or position. The rated voltage<br />
of the motors must be at least as high as the DC-link voltage of the servo amplifier.<br />
The servo amplifiers may only be operated in a closed switchgear cabinet, taking into account the<br />
ambient conditions defined on Page 18. Ventilation or cooling measures may be required to keep<br />
the temperature below 45°C.<br />
Use only copper-cored cables for wiring. The conductor cross-sections can be taken from the European<br />
standard EN 60204 (or Table 310-16 of NEC for 60°C or 75°C in the column for AWG<br />
cross-sections).<br />
We can only guarantee that the system will conform to the standards cited on Page 6 if the components<br />
used are exclusively those supplied by us (servo amplifier, motor, cables etc.).<br />
10 <strong>SERVOSTAR</strong> ® <strong>400</strong> Installation manual