28.11.2012 Views

Digital Servo Amplifier SERVOSTAR 400 - BIBUS SK, sro

Digital Servo Amplifier SERVOSTAR 400 - BIBUS SK, sro

Digital Servo Amplifier SERVOSTAR 400 - BIBUS SK, sro

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

General 07/03 Kollmorgen<br />

1.2 Use as directed<br />

The servo amplifiers are components which are built into electrical equipment or machines, and can<br />

only be commissioned as integral components of such equipment.<br />

The manufacturer of the machine must produce a hazard analysis for the machine and<br />

take appropriate measures to ensure that unforeseen movements do not result in personal<br />

injury or material damage.<br />

Use the servo amplifiers only on the following types of supply:<br />

1 x 115V AC (only <strong>SERVOSTAR</strong> 40xM, unearthed operation is permissible)<br />

3 x 115V AC (only <strong>SERVOSTAR</strong> 40xM, unearthed operation is permissible)<br />

1 x 230V AC (only <strong>SERVOSTAR</strong> 40xM, unearthed operation is permissible)<br />

3 x 230V AC (all types, unearthed operation is permissible)<br />

3 x <strong>400</strong>V AC (only <strong>SERVOSTAR</strong> 44xM, TN-system or TT-system with earthed<br />

neutral point, max. 5000A symmetrical rated current)<br />

If the servo amplifiers are used in residential areas, or in business or commercial premises, then<br />

additional filter measures must be implemented by the user.<br />

The <strong>SERVOSTAR</strong> <strong>400</strong> family of servo amplifiers is only intended to drive specific brushless synchronous<br />

servomotors with closed-loop control of torque, speed and/or position. The rated voltage<br />

of the motors must be at least as high as the DC-link voltage of the servo amplifier.<br />

The servo amplifiers may only be operated in a closed switchgear cabinet, taking into account the<br />

ambient conditions defined on Page 18. Ventilation or cooling measures may be required to keep<br />

the temperature below 45°C.<br />

Use only copper-cored cables for wiring. The conductor cross-sections can be taken from the European<br />

standard EN 60204 (or Table 310-16 of NEC for 60°C or 75°C in the column for AWG<br />

cross-sections).<br />

We can only guarantee that the system will conform to the standards cited on Page 6 if the components<br />

used are exclusively those supplied by us (servo amplifier, motor, cables etc.).<br />

10 <strong>SERVOSTAR</strong> ® <strong>400</strong> Installation manual