Kollmorgen 07/03 Installation<br />
2.3.5.2 Technical data of connecting cables<br />
Further information on the chemical, mechanical and electrical characteristics of the cables can be<br />
obtained from our customer support.<br />
Insulation material<br />
Sheathing PUR (polyurethane, code 11Y)<br />
Core insulation PETP (polyesteraphthalate, code 12Y)<br />
Capacitance<br />
Motor cable less than 150 pF/m<br />
RES/encoder cable less than 120 pF/m<br />
Technical data<br />
— The brackets in the cable designation indicate the shielding.<br />
— All cables are suitable for use as trailing cables.<br />
— The technical data refer to the use as moveable cables.<br />
operating life : 1 million bending cycles<br />
— The permissible operating temperature range is from -30°C to +80°C.<br />
— All cables are colour-coded according to IEC 757.<br />
Cores<br />
[mm²]<br />
External diameter<br />
[mm]<br />
Bending radius<br />
[mm]<br />
Remarks<br />
(4x1.0) 10 100 Motor cable<br />
(4x1.0+(2x0.75)) 10.5 100<br />
Motor cable with extra cores<br />
for controls<br />
(4x2x0.25) 6.9 60<br />
(7x2x0.25) 9.9 80 twisted pairs<br />
(10x2x0.14) 8.8 80<br />
<strong>SERVOSTAR</strong> ® <strong>400</strong> Installation manual 33