Commissioning 07/03 Kollmorgen<br />

The following instructions should help you to carry out the commissioning in a sensible order, without<br />

any hazards to people or machinery.<br />

Check installation<br />

Negate enable signal<br />

Switch on 24V<br />

aux. supply<br />

Switch on PC, start<br />

setup S/W<br />

Check the displayed<br />

parameters, and<br />

correct them if<br />

necessary<br />

See Chapter 2. Disconnect the servo amplifier from the supply.<br />

0V on terminal X1/3 (Enable)<br />

24V DC on terminal 0/1, ground on terminal X0/2<br />

After the initialization procedure (about 0.5 sec.) the status is<br />

shown in the LED display (� p.58)<br />

Select the interface to which the servo amplifier is connected.<br />

The parameters which are stored in the SRAM of the servo<br />

amplifier are transferred to the PC.<br />

Caution !<br />

Check the parameters described below especially carefully.<br />

If you ignore these basic data, system components may be<br />

damaged or destroyed.<br />

Supply voltage : set to the actual mains supply voltage<br />

(observe supply voltage limits, � p.17)<br />

Rated motor voltage : at least as high as the DC-link voltage of the amplifier<br />

Motor pole-no. : must match the motor (see motor manual)<br />

Feedback : must match the feedback unit in the motor<br />

IRMS<br />

: maximum is the motor standstill current I0 (as on nameplate)<br />

IPEAK<br />

: maximum is 4 x motor standstill current I0<br />

Limit speed : maximum is the rated motor speed (as on nameplate)<br />

Regen power : maximum is the rated dissipation for the regen resistor<br />

Station address : unique address on the master<br />

Check safety devices<br />

Switch on power<br />

Apply 0V setpoint<br />

Enable amplifier<br />

Setpoint<br />

Optimization<br />

Commission fieldbus<br />

Caution !<br />

Make sure that any unintended movement of the drive<br />

cannot cause danger to machinery or personnel.<br />

through the ON/OFF button of the contactor control<br />

apply 0V to terminals X3/2-3<br />

(500 msec after switching on the supply power) 24V DC on<br />

terminal X1/3 (Enable), motor is at rest with standstill torque M0<br />

apply a small analog setpoint (about 0.5V is recommended) to<br />

terminals X3/2-3<br />

If the motor oscillates, the Kp parameter in the screen page<br />

Speed controller must be reduced – the motor is in danger !<br />

optimize the speed, current and position controllers<br />

see commissioning instructions in the corresponding<br />

manual on the CD-ROM<br />