Kollmorgen 07/03 Commissioning<br />
4.2 Parameterization<br />
A default parameter set is loaded into your servo amplifier at the factory. This contains valid and<br />
safe parameters for the current and speed controllers.<br />
A database for motor parameters is stored in the servo amplifier. During commissioning you must<br />
select the data set for the motor that is connected and store it in the servo amplifier. For most applications<br />
these settings will already provide good to very good control loop characteristics.<br />
An exact description of all parameters and the options for optimizing the control loop characteristics<br />
can be found in the manual “Setup Software DRIVE.EXE”.<br />
4.2.1 Multi-axis systems<br />
Axis module 1<br />
X8<br />
PC<br />
All the axes in a system can be parameterized through the RS232 interface in the master. To do<br />
this, there is an internal connection between the master and the axis modules. The PC cable only<br />
has to be connected to the master.<br />
The internal address assignment is carried out automatically, so that it is only necessary to set up<br />
the basic station address for the master.<br />
Axis module 2<br />
Axis module 3<br />
Master<br />
COMx<br />
RS232<br />
After changing the station address it is necessary to turn off the 24V auxiliary<br />
supply, and then turn it on again.<br />
Starting at the master, descending addresses are assigned automatically to the axis modules. The<br />
following table shows an example with one master and three axis modules:<br />
Axis Address Remark<br />
Master 10 Master address, set by user<br />
Axis module 3 9<br />
Axis module 2 8 assigned automatically<br />
Axis module 1 7<br />
The highest permitted master address is 128. When choosing the master address, please<br />
consider that at least address 1 will be assigned to the last (leftmost) axis module.<br />
In CAN and PROFIBUS field bus systems the automatically assigned addresses must<br />
not match the address of other nodes.<br />