Kollmorgen 07/03 Appendix<br />
6 Appendix<br />
6.1 Transport, storage, maintenace, disposal<br />
Transport: — only by qualified personnel<br />
— only in the manufacturer’s original recyclable packaging<br />
— avoid shocks<br />
— temperature -25 to +70°C, max. rate of change 20°C/hour<br />
— humidity max. 95% relative humidity, no condensation<br />
— the servo amplifiers contain electrostatically sensitive components<br />
— which can be damaged by incorrect handling. Discharge yourself<br />
— before touching the servo amplifier. Avoid contact with highly<br />
— insulating materials (artificial fabrics, plastic films etc.).<br />
— Place the servo amplifier on a conductive surface.<br />
— if the packaging is damaged, check the unit for visible damage.<br />
— In such a case, inform the shipper and the manufacturer.<br />
Packaging: — recyclable cardboard with inserts<br />
— dimensions <strong>SERVOSTAR</strong> 4xxA (HxWxD) 100x300x270 mm<br />
<strong>SERVOSTAR</strong> 4xxM (HxWxD) 150x300x270 mm<br />
— labelling instrument label on outside of box<br />
Storage : — only in the manufacturer’s original recyclable packaging<br />
— the servo amplifiers contain electrostatically sensitive components<br />
— which can be damaged by incorrect handling. Discharge yourself<br />
— before touching the servo amplifier. Avoid contact with highly<br />
— insulating materials (artificial fabrics, plastic films etc.).<br />
— Place the servo amplifier on a conductive surface.<br />
— max. stacking height: 8 cartons<br />
— storage temp. –25 to +55°C, max. rate of change 20°C/hr<br />
— humidity relative humidity max. 95%, no condensation<br />
— storage duration < 1 year without restriction<br />
> 1 year: capacitors must be re-formed before<br />
the servo amplifier is commissioned.<br />
To do this, remove all electrical connections and<br />
supply the servo amplifier for about 30 min. from<br />
230V AC, single-phase, on terminals L2 / L3.<br />
Maintenance: — the instruments do not require any maintenance<br />
— opening the instruments invalidates the warranty<br />
Cleaning : — if the casing is dirty : cleaning with Isopropanol or similar<br />
do not immerse or spray<br />
— if there is dirt inside the unit: to be cleaned by the manufacturer<br />
— dirty protective grill (fan) : clean with a dry brush<br />
Disposal : — you can dismantle the servo amplifier into its principal components<br />
— by screwing it apart (aluminium heat sink, steel housing sections,<br />
— electronics boards)<br />
— disposal should be carried out by a certified disposal company.<br />
— We can give you suitable addresses on request.<br />
<strong>SERVOSTAR</strong> ® <strong>400</strong> Installation manual 67