Appendix 07/03 Kollmorgen<br />

6.3 Glossary<br />

C clock Clock signal<br />

common-mode voltage The maximum amplitude of a disturbance (on both<br />

inputs) which a differential input can eliminate<br />

continuous power of regen circuit Mean power which can be dissipated in the regen circuit<br />

counts Internal count pulses, 1 pulse = 1/2 20 turn -1<br />

current controller Regulates the difference between the current setpoint<br />

and the actual value to 0<br />

Output : power output voltage<br />

D DC-link Rectified and smoothed power voltage<br />

disable Removal of the enable signal (0V or open)<br />

E earth short electrical connection between a phase and<br />

the protective earth (PE)<br />

enable Enable signal for the servo amplifier (+24V)<br />

F fieldbus interface CANopen, PROFIBUS, SERCOS<br />

free convection Free movement of air for cooling<br />

G GRAY-code Special format for representing binary numbers<br />

H holding brake Brake in the motor, which should only be used when the<br />

motor is at standstill<br />

I I²t threshold Monitoring of the r.m.s. current that is actually required<br />

incremental encoder interface Position signalling by 2 signals with 90° phase<br />

difference, not an absolute position output<br />

input drift Temperature and age-dependent alteration of an<br />

analog input<br />

Ipeak, peak current The effective value of the peak current<br />

Irms, effective current The r.m.s. value of the continuous current<br />

K Kp, P-gain Proportional gain of a control loop<br />

L limit speed Maximum value for speed normalization at ±10V<br />

limit-switch Switch limiting the traverse path of the machine;<br />

implemented as n.c. (break) contact<br />

M machine The complete assembly of all connected parts or<br />

devices, of which at least one is movable<br />

motion-block Set of all the position control parameters<br />

which are required for a motion task<br />

multi-axis system Machine with several driven axes<br />

N natural convection Free movement of air for cooling<br />

O optocoupler Optical connection between two electrically<br />

independent systems<br />