12.07.2015 Views

GPT-3000 SERIES - FLT Geosystems

GPT-3000 SERIES - FLT Geosystems

GPT-3000 SERIES - FLT Geosystems

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

22 ERROR DISPLAYS22 ERROR DISPLAYSError code Description Countermeasures3 pointsrequiredCALCERRORDELETEERRORSIGNALOVERE35E60’sE71E72E73E80’sE90’sFILEEXISTSFULLFILESFAILEDINITIALIZELIMITOVERMEMORYERRORWhen area calculating, there are lessthan 3 points coordinate data inselected file.Calculation is impossible from thedata input.When deleting coordinate data, it can notbe done successful.Displayed when you measure a prism of shortdistance with non-prism mode, or when thetelescope received too much light.Displayed when REM measurementcarried out to the range from zenith ornadir ±6°.Any abnormality occurs with EDM (distancemeasuring system).Displayed when vertical angle 0 position isset with incorrect procedure.Displayed when Vertical angle -position isadjusted in wrong position.The instrument was not leveled when Verticalangle 0-position is adjusted.Mainly at the time data transmissionbetween <strong>GPT</strong>-<strong>3000</strong> series and externalinstrument.Abnormality in internal memorysystem.The same file name exists.When making a file, 30 files already exist.Initializing can not be done successful.Limit of input data exceeded.Any abnormality occurs with internalmemory.Confirm the file data and calculateagain.Confirm the input data.Confirm the data and delete again.Measure the distance by using a targetwithout using a prism, or change the modefrom non-prism mode to prism mode.Operate in the range out of ± 6° from thezenith or nadir.Repair is required.Confirm the procedure and readjust.Repair is required.Level the instrument then carry theadjustment work.Confirm operation procedure is correct or theconnection cables are correct.Repair is required.Use another file name.If necessary, send or delete files.Confirm initializing data and try toinitialize again.Input again.Initialize the internal memory.MEMORYPOORNO DATAShortage of capacity of the internalmemory.The data is not found in the searchmodeDownload data from internal memoryto PC.Confirm the data and search again.NO FILE There is no file in internal memory. If necessary, make files.FILE NOTSELECTEDWhen using a file, no file is selected.Confirm the file and select a file.P1-P2distancetoo shortWhen in point to line measurement, thehorizontal distance between first point andsecond point is within 1m.The horizontal distance between firstpoint and second point must be morethan 1m.22-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!