7 DATA COLLECTION7.5.2 Executing a point to line measurementOperating procedure Operation DisplayConduct data measurement according to the sameprocedure as with ordinary FS/SS (ALL can also beselected). However, when you conduct observation inthe angle mode, PTL data will not be displayed (onlythe raw data will be recorded, upon which theoperation will end).1 Press the [F3](MEAS) key. [F3][F4]PT#PTL→PT-01PCODE :TOPCONR.HT : 1.500 mINPUT SRCH MEAS ALLPT# →PT-01PCODE :TOPCONR.HT : 1.500 mVH *SD NEZ P1↓2 Press the [F2](SD) key.If the PTL mode is on, then, after the coordinatedata is calculated, the PTL data will be displayedregardless of the coordinate check setting, etc.3 PTL measurement data will display.Confirm the data and press [F3](YES) key.The recorded data are measured data andcoordinate data generated at the same time as aPTL data.[F2][F3]V : 90°10'20"HR: 120°30'40"SD*< m> Measuring...L: 44.789 mO: 33.456 mE: 2.321 m>REC? [YES][NO]PT#PTL→PT-02PCODE :TOPCONR.HT : 1.500 mINPUT SRCH MEAS ALL●In the PTL measurement mode, NEZ Auto Calculation wil be turned on compulsorily and the coordinatedata will be stored into a coordinate file.7-19