Runoff Volume/ Infiltration<br />

Runoff Volume/<br />

Non-infiltration<br />

Runoff Quality/ Non-infiltration<br />

Restoration<br />

Table 7.1<br />

BMP Summary Matrix<br />

Potential Applications<br />

Residential Commercial Ultra Urban Industrial Retro Road Rec<br />

Bioretention YES YES LIMITED LIMITED YES YES YES<br />

Vegetated Filter Strip YES YES LIMITED 2 LIMITED YES YES YES<br />

Vegetated Swale YES YES LIMITED 2 YES LIM YES YES<br />

Pervious Pavement YES 3 YES YES YES 3 YES 3 LIM 3 YES<br />

Infiltration Basin YES YES LIMITED 2 YES LIM LIM NO<br />

Subsurface Infiltration Bed YES YES YES YES YES LIM NO<br />

Infiltration Trench YES YES YES YES YES YES NO<br />

Dry Well YES YES YES LIMITED YES NO NO<br />

Level Spreaders YES YES NO YES YES YES YES<br />

Berming YES YES LIMITED 2 YES YES YES NO<br />

Planter Box YES YES YES LIMITED YES NO LIM<br />

Vegetated Roof LIMITED YES YES YES YES N/A YES<br />

Capture Reuse YES YES YES YES YES NO YES<br />

Constructed Wetland YES YES YES YES YES YES YES<br />

Wet Ponds/<br />

Retention Basins<br />

YES YES YES YES YES YES YES<br />

Constructed Filters LIMITED YES YES YES YES YES YES<br />

Water Quality Devices YES YES YES YES YES YES YES<br />

Underground Detention YES YES YES YES YES YES YES<br />

Extended Detention/<br />

Dry Pond<br />

Riparian Buffer<br />

Restoration<br />

YES YES YES YES YES YES YES<br />

YES YES YES YES YES LIM YES<br />

Native Revegetation YES YES LIMITED YES YES LIM YES<br />

Soil Restoration YES YES YES YES LIM YES YES<br />

Notes:<br />

1 Reported as TN except as noted as (NO3 )<br />

2 Difficult to apply due to space limitations typically associated with these land uses.<br />

3 Applicable with special design considerations<br />

4 This assumes TSS loads and their debris have been managed properly be<strong>for</strong>e entering the BMP to prevent clogging.<br />

5 Requires infiltration planter box.<br />