FX'WA TECHKICAL ADVISORY T 5080.17<br />

July 14, 1994<br />

ATTACHLYENT 3<br />

(b) Is a 1/3T deep groove being sawed over each<br />

assembly as soon as possible after concrete<br />

placement? Cleaned immediately?<br />

(cl Are all joints being sealed after the curing<br />

period and before opening to traffic?<br />

23. TRANSVERSE CONSTRUCTION JOINTS ICONTINUOUSLY REINFORCED<br />

CONCRETE)<br />

(4<br />

(b)<br />

(cl<br />

(d)<br />

W<br />

Are construction joints being placed at the<br />

end of each day's operation or after an<br />

interruption in the concreting operation of<br />

30 minutes or more?<br />

Are construction joints being placed at least<br />

1 meter from nearest bar lap?<br />

Are construction joints strengthened by<br />

supplementary 1.8 meter long bars of the same<br />

nominal diameter as the longitudinal steel so<br />

that the area of steel through the joint is<br />

increased by at least l/3?<br />

Are construction joints formed.by means of a<br />

clean (not oiled) split header board<br />

conforming to the cross section of the<br />

<strong>pavement</strong>?<br />

Is the concrete at construction joints being<br />

given supplemental internal vibration along<br />

the length of the joint both at the end of<br />

the day's operation and once again at the<br />

resumption on the next day? This is<br />

critical.<br />

24. TRANSVERSE CONSTRUCTION JOINTS (JOINTED PAVEMENT1<br />

(a) Are construction joints being placed at the<br />

end of each day's operation or after an<br />

- interruption in the concreting operation of<br />

30 minutes or more?<br />

(b) Are construction joints being placed at least<br />

3 meters from any transverse joint?<br />

3.10.38