Technical Article<br />

The article “Ask the Doctors: Modeling of the Neve 33609 compressor/limiter”<br />

contains interesting technical details about the 33609. It is available at<br />

our online webzine:<br />

• http://www.uaudio.com/webzine/2006/august/index2.html<br />

Neve 33609 Controls<br />

Each feature of the <strong>UAD</strong> Neve 33609 interface is detailed below.<br />

Limiter<br />

Controls in this section only function<br />

when the limiter is enabled with the<br />

“limit In” switch (the Power switch must<br />

also be on).<br />

Note: The compressor precedes the limiter<br />

(see “Signal Flow” on page 158).<br />

Limiter<br />

Threshold<br />

Threshold determines how much limiting will occur. When the input signal exceeds<br />

the threshold level, the signal above the threshold is limited. A smaller<br />

value results in more limiting. The available range is from +4dB to +15dB, in<br />

.5dB increments.<br />

If the compressor is enabled, the Gain control in the compressor section<br />

(“Compressor Gain” on page 160) will affect the input level into the limiter.<br />

In this case, the compressor gain can affect the limiter threshold response.<br />

Limiter Recovery<br />

Recovery (release) is the time it takes for the limiter to stop processing after the<br />

signal drops below the threshold value. The available values (in milliseconds)<br />

are 50, 100, 200, 800, a1, and a2.<br />

The automatic settings (a1 and a2) are program dependant. The value for a1<br />

can be as fast as 40ms, but after a sustained period of high signal level, the<br />

period is ≈1500ms. The value for a2 can be as fast as 150ms, but after a sustained<br />

period of high signal level, the period is ≈3000ms.<br />

Limiter In<br />

This toggle switch enables the limiter portion of the plug-in. The limiter has no<br />

effect unless this switch is in the “In” (down) position.<br />