Note: As the Threshold control is increased and more processing occurs, output<br />

level is typically reduced. Adjust the Gain control to modify the output of<br />

the module to compensate if desired.<br />

L/C Threshold<br />

–20dB<br />

The –20dB switch increases the sensitivity of the limiter/compressor<br />

by lowering the range of the available threshold values. When<br />

–20dB mode is active, the threshold range is 0dB to –30dB. When<br />

–20 is inactive, the threshold range is +20dB to –10dB.<br />

To activate –20dB mode, click the “pull –20” label text or the red indicator<br />

just below the Threshold control. –20dB mode is active when the red indicator<br />

illuminates.<br />

L/C Ratio (RAT)<br />

Ratio defines the amount of gain reduction to be processed by<br />

the module. For example, a value of 2 (expressed as a 2:1 ratio)<br />

reduces the signal by half, with an input signal of 20 dB<br />

being reduced to 10 dB.<br />

A value of 1 yields no gain reduction. When the control is at<br />

maximum (“lim”), the ratio is effectively infinity to one, yielding the limiting effect.<br />

The available range is 1 to infinity.<br />

L/C Fast<br />

The Fast mode switch defines the attack time (the duration between<br />

the input signal reaching the threshold and processing being applied)<br />

of the limiter and compressor.<br />

Attack time is program dependent. Two ranges are available: 3<br />

milliseconds to 7 milliseconds (Fast off) and 1 millisecond to 7 milliseconds<br />

(Fast active).<br />

To activate Fast mode, click the “pull FAST” label text or the red indicator just<br />

below the Ratio (RAT) control. Fast mode is active when the red indicator illuminates.<br />

L/C Release<br />

Release sets the amount of time it takes for processing to<br />

cease once the input signal drops below the threshold level.<br />

The available range is 10 milliseconds to 3 seconds, and automatic.<br />

Automatic triple time-constant program dependent release<br />

time is activated by turning the release control fully clockwise<br />

(to 3s) or by clicking the “AUTO” label text.<br />