TO 1-1-700 - Robins Air Force Base
TO 1-1-700 - Robins Air Force Base
TO 1-1-700 - Robins Air Force Base
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>TO</strong> 1-1-<strong>700</strong><br />
8.6.3 Cleaning Procedures/Selection Criteria. Always<br />
select the mildest method of cleaning that will accomplish the<br />
task. Circuit components can be damaged if cleaned using the<br />
wrong support equipment. The method used shall be based on:<br />
a. Type and severity of the contamination or corrosion.<br />
b. Accessibility of the contamination or corrosion.<br />
c. Type of electronic equipment.<br />
8.6.3.1 Hazards of Cleaning. Always use the gentlest<br />
materials and cleaning methods that will ensure complete<br />
cleaning or corrosion removal. In addition, always use the<br />
correct cleaning solutions mixed to the proper concentrations.<br />
Substitutions are not permitted. Using incorrect equipment, or<br />
solutions in high concentrations can result in damage to electronic<br />
components.<br />
8.6.3.1.1 Solvent entrapment - solvents, detergents, or water<br />
may become trapped in crevices or cavities. This will interfere<br />
with additional cleaning or refinishing operations. In addition,<br />
it can prevent correct operation of the electronic equipment<br />
after the repair is complete.<br />
c. Ensure that drain and vent holes are open.<br />
d. Remove covers, doors, etc.<br />
e. Disassemble or remove from enclosures if practical and<br />
necessary for the required cleaning.<br />
f. Verify the availability of authorized cleaning materials.<br />
g. Double-check the compatibility of cleaning materials<br />
before use.<br />
h. Mask vulnerable components to prevent the entrance of<br />
water, solvents, or detergents.<br />
8.6.3.4 Cleaning and Drying Restrictions. Some circuit<br />
components are vulnerable to damage during the cleaning process.<br />
Usually, the potential for this damage can be minimized<br />
prior to cleaning. The biggest contributing factor to this damage<br />
is water or solvent trapped by a component. Vulnerable<br />
components and techniques to minimize their vulnerabilities<br />
are shown in Table 8-6. Procedures for sealing components are<br />
as follows:<br />
8.6.3.1.2 Over scrubbing - prolonged abrasive scrubbing can<br />
cause delamination in printed circuit boards.<br />
8.6.3.1.3 Solvent attack - certain solvents can soften conformal<br />
coatings, wire insulation, acrylics, and some circuit components.<br />
Do not substitute solvents in the cleaning process.<br />
8.6.3.2 When to Clean. Immediate cleaning shall occur<br />
whenever any of the following conditions exist:<br />
8.6.3.2.1 Electronics have been exposed to adverse weather<br />
or salt-water spray.<br />
8.6.3.2.2 Electronics have been exposed to fire-extinguishing<br />
agents.<br />
8.6.3.2.3 Batteries have discharged electrolyte solution on or<br />
near electronic components.<br />
8.6.3.2.4 Repair is necessary because of corrosion or component<br />
failure.<br />
8.6.3.3 Precleaning Treatment. Accomplish the following<br />
before starting a cleaning operation:<br />
a. Disconnect any external power supply from electronics.<br />
TT-I-735, ALCOHOL, ISOPROPYL 65<br />
a. Seal small components with SAE-AMS-T-21595, Pressure<br />
Sensitive Tape. Ensure tape and tape residue are<br />
removed using Solvent Cleaning followed by wiping<br />
with TT-I-735 Isopropyl Alcohol prior to drying the<br />
equipment.<br />
b. Seal large components in plastic bags or seal with MIL-<br />
PRF-131 Water Vapor Proof Barrier Material. Place the<br />
bag or barrier material around the component and seal<br />
with SAE-AMS-T-21595 Pressure Sensitive Tape.<br />
Ensure tape, tape residue, and bag or barrier materials<br />
are removed using Solvent Cleaning followed by wiping<br />
with TT-I-735 Isopropyl Alcohol prior to drying the<br />
component.<br />
c. In some cases the component may be removed from the<br />
equipment without too much difficulty. When this is<br />
possible, the removed component shall be cleaned separately.<br />
This method is preferred for any component that<br />
can be easily removed.<br />
b. Remove batteries.<br />
8-27