Table 7-1. Cleaning of Specific Areas and Components - Continued<br />
Area or<br />
Component<br />
Type of<br />
Contaminant<br />
Cleaning Agent<br />
Mixing<br />
Directions and<br />
Nomenclature<br />
Cleaning Procedures<br />
MIL-PRF-680 AND A-A-59601, SOLVENT, DEGREASING, TYPE II AND III 45<br />
MIL-PRF-85570, CLEANING COMPOUND, AIRCRAFT 51<br />
MIL-PRF-87937, CLEANING COMPOUND, AIRCRAFT 52<br />
BATTERY<br />
COMPARTMENTS<br />
- Continued<br />
Lead-acid battery<br />
electrolyte deposits<br />
(sulfuric acid solution)<br />
ASTM D 928<br />
MIL-PRF-81309, Type<br />
II, Class 1 or 2, or<br />
MIL-L-87177, Type I<br />
or II, Grade B<br />
Sodium Bicarbonate,<br />
6 oz in 1<br />
gallon water<br />
Water Displacing<br />
CPC<br />
Remove spilled electrolyte<br />
immediately by flushing with<br />
fresh water. Spray the contaminated<br />
area with Litmus solution<br />
(Refer to <strong>TO</strong> 1-1-691, Chapter<br />
7). Neutralize the area by sponging<br />
or spraying with sodium<br />
bicarbonate solution. Apply<br />
generously until bubbling stops<br />
and the Litmus solution turns<br />
blue. Let it stay on the surface<br />
for 5 minutes, but do not allow<br />
to dry. Brush with a fiber bristle<br />
brush, then flush with fresh<br />
water. Reapply the Litmus solution<br />
to determine if all electrolyte<br />
has been neutralized.<br />
Retreat the area as required and<br />
rinse. Dry with clean wiping<br />
clothes. Keep the cell vents open<br />
but do not allow an solutions to<br />
enter the cells. Preserve compartment<br />
with MIL-PRF-81309,<br />
Type II, Class 1 or 2 or MIL-L-<br />
87177, Type I or II, Grade B<br />
CPC. Do not paint or preserve<br />
batteries.<br />
BILGE AREAS<br />
Hydraulic fluid,<br />
water, dirt, metallic<br />
debris<br />
MIL-PRF-87937, Type<br />
IV or MIL-PRF-85570,<br />
Type II<br />
or<br />
1 part cleaner in<br />
9 parts water<br />
Vacuum clean liquids and<br />
debris. Wipe area with a sponge<br />
dampened in cleaning solution.<br />
Rinse by sponging with fresh<br />
water. Wipe dry with a clean<br />
cloth.<br />
Change 1 7-11