TO 1-1-700 - Robins Air Force Base
TO 1-1-700 - Robins Air Force Base
TO 1-1-700 - Robins Air Force Base
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>TO</strong> 1-1-<strong>700</strong><br />
Table 12-1. Sealing Compounds - Continued<br />
Specification Types Available Properties Intended Use<br />
PR-1773, SEALING COMPOUND, LOW ADHESION,<br />
NON-CHROMATE CORROSION INHIBI<strong>TO</strong>RS 57<br />
PR-1773, (supersedes PR-<br />
1403G), Sealing Compound,<br />
Non-Chromate Corrosion<br />
Inhibitive Polysulfide Rubber<br />
Cage Code #83574<br />
SAE AMS-3267 (MIL-S-8784), SEALING<br />
COMPOUND, RUBBER, HEAT RESISTANT 58<br />
Class B (thick) - for<br />
sealant gun or spatula<br />
application<br />
Two-components;<br />
Room Temp Cure;<br />
Service Temp: -65 ºF to +250 ºF<br />
(-54 °C to +121 °C);<br />
Peel strength: 2 lb/in width (max)<br />
Preferred sealant for general<br />
purpose, low adhesion sealing<br />
of access doors, floor<br />
panels and plates, removable<br />
panels, and Formed-in-Place<br />
(FIP) gaskets in non-fuel<br />
areas. Can be used to repair<br />
defects in FIP Gaskets.<br />
Corrosion inhibitors;<br />
Resists fuel, oil, and hydraulic<br />
fluid.<br />
SAE AMS 3267 /1, /2, /3, & /4<br />
(supersedes MIL-S-8784),<br />
Sealing Compound, Low Adhesion,<br />
Corrosion Inhibiting, For<br />
Removable Panels and Fuel<br />
Tank Inspection Plates<br />
/1= Class A-1/2<br />
/2= Class B-1/2<br />
/3= Class A-2<br />
/4= Class B-2<br />
Class A (thin) - for<br />
brush application<br />
Class B (thick) - for<br />
sealant gun or spatula<br />
application<br />
Two-components;<br />
Room temp cure;<br />
Service temp: -65 ºF to +250 ºF<br />
(-54 °C to +121°C);<br />
Peel strength: 4lb/in width (max);<br />
Corrosion inhibitors;<br />
Resists fuel, oil, and hydraulic<br />
fluid.<br />
Polysulfide rubber sealing<br />
compound for fillet and faying<br />
surface sealing of removable<br />
structure such as access<br />
doors, floor panels and<br />
plates, removable panels, and<br />
fuel tank inspection plates.<br />
Not for high temp areas or<br />
permanent structure.<br />
12-4