<strong>TO</strong> 1-1-<strong>700</strong><br />
Table 7-1. Cleaning of Specific Areas and Components - Continued<br />
Area or<br />
Component<br />
Type of<br />
Contaminant<br />
Cleaning Agent<br />
Mixing<br />
Directions and<br />
Nomenclature<br />
Cleaning Procedures<br />
MIL-PRF-680 AND A-A-59601, SOLVENT, DEGREASING, TYPE II AND III 45<br />
MIL-PRF-85570, CLEANING COMPOUND, AIRCRAFT 51<br />
MIL-PRF-87937, CLEANING COMPOUND, AIRCRAFT 52<br />
Nickel-cadmium batteries must not be exposed to acid or acid vapors. Battery electrolytes are extremely<br />
corrosive. Spilled electrolyte shall be removed immediately. Refer to applicable system specific aircraft,<br />
missile, or equipment manuals for battery type. Fumes from overheated electrolyte will spread to adjacent<br />
areas, causing rapid corrosion on unprotected surfaces.<br />
BATTERY<br />
COMPARTMENTS<br />
Nickel-cadmium<br />
battery electrolyte<br />
deposits (potassium<br />
hydroxide solution)<br />
A-A-59282<br />
or<br />
ANSI/AWWA B 504<br />
MIL-PRF-81309, Type<br />
II, Class 1 or 2, or<br />
MIL-L-87177, Type I<br />
or II, Grade B<br />
Boric Acid<br />
Monobasic<br />
sodium phosphate<br />
Mix either material<br />
6 oz in 1 gallon<br />
water<br />
Water Displacing<br />
CPC<br />
Remove spilled electrolyte<br />
immediately by flushing with<br />
fresh water. Spray the contaminated<br />
area with Bromothymol<br />
Blue solution (Refer to <strong>TO</strong> 1-1-<br />
691, Chapter 7). Neutralize the<br />
area by sponging or spraying<br />
generously with boric acid or<br />
sodium phosphate solution.<br />
Brush with a fiber bristle brush<br />
and flush with fresh water.<br />
Reapply the Bromothymol Blue<br />
solution to determine if all the<br />
electrolyte has been neutralized.<br />
Retreat area as required and<br />
rinse. Dry with clean wiping<br />
clothes. Keep the cell vents<br />
open, but do not allow any solutions<br />
to enter the cells. Preserve<br />
compartment with MIL-PRF-<br />
81309, Type II, Class 1 or 2 or<br />
MIL-L-87177, Type I or II,<br />
Grade B CPC. Do not paint or<br />
preserve batteries.<br />
7-10 Change 1