HQ Pro-Stitcher User Manual - Handi Quilter
HQ Pro-Stitcher User Manual - Handi Quilter
HQ Pro-Stitcher User Manual - Handi Quilter
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
The <strong>HQ</strong> <strong>Pro</strong>-<strong>Stitcher</strong> is an upgrade<br />
to a Non-Regulated <strong>HQ</strong> Sixteen<br />
1. Follow the instructions for attaching a new Y-axis<br />
encoder assembly (steps 2-4 above) that came with<br />
the Stitch Regulator Upgrade Kit.<br />
The <strong>HQ</strong> <strong>Pro</strong>-<strong>Stitcher</strong> was purchased<br />
with a new <strong>HQ</strong> Sixteen<br />
1. The correct Y-axis encoder assembly should already<br />
be attached to the <strong>HQ</strong> Sixteen.<br />
Power Cord Retaining Clamp Installation<br />
(<strong>HQ</strong> Sixteen only)<br />
1. Set the <strong>HQ</strong> Sixteen back up on its wheels and<br />
make sure it is unplugged.<br />
2. Remove the four P-Pod mounting screws from<br />
the P-Pod (the plastic box on the left-hand side of the<br />
<strong>HQ</strong> Sixteen which contains the power cord receptacle)<br />
using a Phillips screwdriver. Please note that<br />
the bottom left-hand screw is longer than the other<br />
three.<br />
3. Carefully disconnect all three cables from the<br />
P-Pod.<br />
4. If working with an upgrade that included a new<br />
P-Pod, get it out now and continue the following<br />
steps using the new P-Pod, otherwise the following<br />
steps apply to the P-Pod that was just removed.<br />
5. Loosen the two screws that mount the power<br />
cord receptacle to the plastic P-Pod using a Philips<br />
screwdriver and, if the screws include nuts on the opposite<br />
end, a wrench or small pliers to hold the nut<br />
(the two Phillips head screws are accessible from the<br />
exterior of the pod while the nuts are on the interior).<br />
6. Slide the retaining clamp (Page 16, P) over one<br />
end of the new Y-split power cord (I).<br />
7. Insert the power cord into the receptacle on the<br />
P-Pod while sliding the two slots on the clamp behind<br />
the two screws that were just loosened.<br />
8. Make sure the power cord is fully inserted, and<br />
then tighten the two P-Pod screws so they hold the<br />
clamp securely against the P-Pod. Insert the small<br />
screw included with the retaining clamp into the<br />
clamping portion of the retaining clamp and tighten<br />
so the clamp is now tight on the power cord as<br />
shown in Figure10.<br />
9. Re-connect the three P-Pod cables and then reattach<br />
the P-Pod to the <strong>HQ</strong> Sixteen head (remember,<br />
the long screw should be in the bottom left-hand<br />
hole).<br />
Nuts<br />
Figure 10<br />
Power Cord Clamp (K)<br />
Power<br />
Cord (O)<br />
Page 22<br />
<strong>HQ</strong> <strong>Pro</strong>-<strong>Stitcher</strong> <strong>User</strong> <strong>Manual</strong>