Ethernet Controller Messages<br />

Note: The error messages shown in this section are available only with the<br />

integrated Ethernet controller. These error messages are not available when<br />

remote program load (RPL) or dynamic host configuration protocol (DHCP)<br />

is used through optional network adapters.<br />

If a failure condition occurs after the Ethernet controller is initialized, an error<br />

message appears on the screen. The error messages that can occur are shown in the<br />

following sections. If you experience any error related to the integrated Ethernet<br />

controller, record the error message, and tell your network administrator about the<br />

problem.<br />

The two most common error messages are:<br />

RPL-ROM-ERR: 1�5 The integrated Ethernet failed the loopback test.<br />

RPL-ROM-ERR: 1�7 Media test failed; check the cable.<br />

Error 105 indicates that a power-on diagnostic test performed by the Ethernet<br />

module did not execute correctly. If this error message appears, you must have the<br />

server serviced. Error 107 indicates that the cable from the LAN is not securely<br />

connected to the Ethernet port on your server. Check the cable to ensure that it is<br />

properly connected.<br />