ToC SERVICE MANUAL MARINE ENGINES<br />

05 COOLING SYSTEM<br />

05.00.07 Drain coolant system<br />

Raw water circuit<br />

1 Remove drain plug (ill.1/pos.1).<br />

1<br />

NOTE:<br />

Drain plug (ill.1/pos.1) does not exist<br />

for all models.<br />

2 To drain the raw water ducts on the engine, remove<br />

cover rear of raw water pump (ill.2+3/pos.1).<br />

00.07 ill.1<br />

NOTE:<br />

For complete removal of water residues<br />

from pump housing and water ducts<br />

of raw water circuit, proceed as follows:<br />

3 Lock exhaust pipe with special tool No. VR00144/0<br />

(ill.4/pos.1)<br />

1<br />

4 Remove plug J 1.<br />

Connect special tool No. VR00145/0 instead of plug<br />

J1.<br />

00.07 ill.2<br />

5 Start the engine by pressing the button, until raw<br />

water system is completly emptied.<br />

ATTENTION: Only start with special tool No.<br />

VR00145/0. Engine only be cranked<br />

by starter motor, but not start.<br />

6 After complete drainage, assembly is done in reverse<br />

order.<br />

1<br />

ATTENTION: If the water is not drained in time before<br />

the winter season, this could result in<br />

frost damage on the engine as well as<br />

the drive.<br />

00.07 ill.3<br />

1<br />

00.07 ill.4<br />

Z001019/0_6_July 2008 Page COOLING SYSTEM - 13