ToC<br />

SERVICE MANUAL MARINE ENGINES<br />

GENERAL<br />

Operating Parameter<br />

Effect<br />

noticed<br />

Panel<br />

Indication<br />

Additional<br />

Tool-Readings<br />

Action or<br />

possible reason<br />

Inverse position shut<br />

down (SOLAS)<br />

Engine shut<br />

down beyond<br />

70° deg. angle<br />

After engine stop<br />

horn remains<br />

switched ON until<br />

ignition reset<br />

Reset through ignition<br />

OFF and then ON<br />

During break in phase<br />

Cel-ON at high<br />

accelerator<br />

position (more<br />

than 75%)<br />

Indication light<br />

"CEL" is switched<br />

ON<br />

<strong>Steyr</strong> Diag<br />

Break-in<br />

phase<br />

See information break<br />

in procedure<br />

Optical and accustical warning signals are explained on the following tables.<br />

"Operating Status and Error Report"<br />

D 2<br />

Diagnostic system<br />

The electronic management system monitors the following engine parameters:<br />

oil pressure, boost pressure, coolant temperature, exhaust pipe temperature (Hi-riser), sensor control rack,<br />

potentiometer accelerator, speed signal<br />

The electronic management system carries out self-diagnostic and/or plausibility checks for all input values and<br />

sensor connections. In case of irregularities, there is an optical or audible warning signal. (see page 71)<br />

Existing active failures remain stored until the problem has been solved and the code has been cleared from the<br />

memory.<br />

To select stored error codes, a PC with diagnostic program (VR00134/0) or diagnostic tool (VR00135/1) is<br />

necessary.<br />

Malfunction during operation is ranked in three different categories intermittent failure, non essential failure and<br />