ToC SERVICE MANUAL MARINE ENGINES<br />

06 ELECTRICAL SYSTEM<br />

06.05 CABLES, WIRING HARNESS - GENERAL<br />

Cable / wiring<br />

In case of necessary repair of a cable connection, take special care that cable quality,<br />

isolation, crimping, strand end soldering of cable sockets as well as protective varnish isolation<br />

and/or connector locks meet the respective requirements.<br />

Tools for crimp connections to be found in tool catalog P/N Z001002/0 "KIT 3".<br />

06. 05. 01. Battery cable lengths and cross-sections<br />

Determine the lenght of the positive cable from the positive pole (+) of the battery to connection No.<br />

30 at the starter.<br />

Total lenght is the sum of cable length of positive cable (+) and earth cable (-).<br />

For example:<br />

positive cable = 3,0 m<br />

ground cable = 2,0 m<br />

-----------------------------<br />

Total length = 5,0 m ===> cable cross section = 70 mm²<br />

For ground connection, determine corresponding cross-sections as per chart.<br />

For 4 cyl. engines only<br />

starter engine: 2 kW - 12 volt<br />

battery size: 92 AH<br />

length<br />

in m<br />

0,0 - 4,0<br />

4,1 - 5,0<br />

5,1 - 6,0<br />

cable cross-section<br />

in mm²<br />

50<br />

70<br />

95<br />

AWG<br />

0<br />

00<br />

0000<br />

For 6 cyl. engines only<br />

starter engine: 3 kW - 12 Volt<br />

battery size: 110 AH<br />

length<br />

in m<br />

0,0 - 3,0<br />

3,1 - 4,5<br />

4,6 - 5,5<br />

cable cross-section<br />

in mm²<br />

50<br />

70<br />

95<br />

AWG<br />

0<br />

00<br />

0000<br />

In general, take care that battery cable lengths are kept as short as possible.<br />

Z001019/0_6_July 2008 Page ELECTRICAL SYSTEM - 19