ToC SERVICE MANUAL MARINE ENGINES<br />

Indication status<br />

Fault<br />

ELECTRICAL SYSTEM<br />

Remarks<br />

ON<br />

(2x per sec.)<br />

80° - 90°C<br />

high exhaust<br />

temperature<br />

(off 80° C)<br />

check raw water<br />

system,<br />

strainer, impeller pump<br />

OFF<br />

07.05 ill.4<br />

OFF FLASHING<br />

(2x per sec.)<br />

ON high approx 105°C<br />

(2x per sec.)<br />

engine coolant<br />

temperature to high<br />

after cooling down,<br />

check engine coolant<br />

level<br />

OFF OFF OFF<br />

07.05 ill.5<br />

ON<br />

120°C<br />

(2x per sec.)<br />

defect engine coolant<br />

sensor or<br />

sensor connection<br />

after cooling down,<br />

check engine coolant<br />

level, sensor (B16)<br />

and connection<br />

OFF OFF OFF<br />

07.05 ill.6<br />

OFF<br />

80° - 90°C<br />

instable idle speed,<br />

no indication on<br />

tachometer<br />

defect speed sensor (B15)<br />

or<br />

sensor connection<br />

OFF OFF OFF<br />

07.05 ill.7<br />

ON<br />

80° - 90°C<br />

OFF OFF ON<br />

07.05 ill.8<br />

Trouble in governing loop,<br />

involved components:<br />

control solenoid, rack,<br />

control gear of<br />

unit injector,<br />

rack position sensor<br />

Failure in governing loop:<br />

time limit exceed for rack<br />

positioning. Restriction<br />

or high friction in control<br />

devices.Stored failure code<br />

must be cleared memory.<br />

Tools: PC-service program<br />

Z001019/0_6_July 2008 Page ELECTRICAL SYSTEM - 55