ToC<br />

ELECTRICAL SYSTEM<br />

SERVICE MANUAL MARINE ENGINES<br />

06.12. BATTERY<br />

06.12.01 Battery<br />

Battery - Acid Test<br />

The battery provides the starter engine with energy and supplies the required voltage for lighting and<br />

other electrical equipment when the engine is not running. During the starting procedure and when the<br />

generator does not generate any current, the battery provides the electronic engine management<br />

system with voltage.<br />

For 4 cyl. engines only<br />

Use a 12 V battery with a cold test circuit of 450 ampere at -18°C and a capacity of 92 Ah at 27°C, to<br />

guarantee the supply of the electric and electronic components for all operating conditions.<br />

For 24 V - installation only<br />

Use two 12V batteries with a cold test circuit of 650 ampere each at -18°C and a capacity of 115 Ah<br />

at 27°C, to guarantee the supply of the electric and electronic components for all operating conditions.<br />

The batteries are connected in series and provide a capacity of 115 Ah / 24 V for the external supply<br />

of all electric components on the boat.<br />

12V supply of all electric and electronic components on the engine (including instrument panel) by<br />

center tapping. Additional charge is guaranteed by charging equalization.<br />

For 6 cyl. engines only<br />

Use a 12 V battery with a cold test circuit of 650 ampere at -18°C and a capacity of 115 Ah at 27°C,<br />

to guarantee the supply of the electric and electronic components.<br />

Explanation:<br />

Cold current test:<br />

The cold current test is a specified load test of a battery.The<br />

charge of battery with specified current (e.g. 450A).<br />

After discharge for 30 sec., the voltage should not drop bellow ³9V.<br />

Capacity:<br />

With a current consumption of 1 / 20<br />

of specified capacity (e.g. 92Ah) the battery<br />

voltage must not fall below 10 V after 20 hours, to guarantee the engine's<br />

starting ability.<br />

Maintenance<br />

To guarantee long battery life, the following tests should be carried out periodically.<br />

1 The level of battery acid must always be above plates and separators. The acid level should reach the<br />

marking on the battery. Acid may only be refilled by an expert when it was definitely stated that some<br />

of it has been spilled.<br />

ATTENTION:<br />

Battery fluid is an aggressive acid and must be handled with care. In case of skin<br />

contact rinse thoroughly with water and consult a doctor - physician.<br />