Maintenance and Service<br />

Trouble Check Chart<br />

ATTENTION:<br />

After following the “Action” described in chart, and before cranking the engine, make sure<br />

there are no loose fuel connections. Make sure engine compartment is free of fuel vapours.<br />

Failure to do so could result in fire.<br />

SYMPTOM POSSIBLE CAUSE ACTION<br />

Engine won’t start 1. No fuel in tank or shut-off valve Fill tank or open valve.<br />

closed.<br />

2. Air leak in suction lines. Bleed fuel system and check for leaks.<br />

3. Fuel line plugged or pump Fuel pump may be defective.<br />

defective.<br />

4. Poor fuel quality. Replace fuel .<br />

5. Water in fuel filter. Replace or drain water from fuel filter.<br />

Check fuel supply for water contamination. If water<br />

is present, drain fuel tank and flush with fresh fuel.<br />

6. System error or failure. Check Engine Management System<br />

display for service code.<br />

7. Battery output insufficient Charge or replace battery.<br />

Only for SOLAS ==> 8. Inversion switch actuated Cancelled by ignition "OFF - ON"<br />

Starter won’t crank 1. Battery connections loose or Check for loose connections<br />

engine corroded and corrosions. Clean connections and<br />

thighten.<br />

2. Battery is dead Check level of electrolyte and charge<br />

battery.<br />

3. Starter connections loose Check connections and tighten.<br />

If solenoid clicks when attempting to<br />

start engine, check starter.<br />

4. Ignition switch If inoperative, replace.<br />

5. Fuse blown on panel Check and replace if defect<br />

6. Starter auxiliary relay Check terminal connection and function of relay.<br />

Engine runs erratically 1. Water, air and/or dirt in fuel filter Replace filter. Inspect fuel supply line.<br />

2. Anti-siphon valve stuck Clean and inspect or replace. (Tank)<br />

3. Fuel pump Check operation of pump.<br />

Replace fuel pump.<br />