ToC SERVICE MANUAL MARINE ENGINES<br />

06 ELECTRICAL SYSTEM<br />

For 6 cyl. engines only (old version till eng. no. 68224418)<br />

circuit diagr.:<br />

Governor<br />

01.03 ill.2<br />

01.03 ill.3<br />

Check of alternator and connections:<br />

With engine stopped, measure voltage on alternator (+output and -output).<br />

Measured voltage may be lower than the battery voltage by (up to) 1 volt only.<br />

Where appropriate, test wiring of cables and connections.<br />

Check of control voltage and/or alternator voltage:<br />

NOTE:<br />

For these works, the battery's state of charge should be 95% at least.<br />

Check tension of belt on alternator drive and make sure that cables are perfectly connected.<br />

1. Disconnect all electrical consuming devices and adjust engine to a speed of approx. 1000 rpm.<br />

2. Connect voltmeter to alternator output "B +".<br />

3. Remove plastic screw on governor and apply screw driver with fine blade on adjusting screw.<br />

ATTENTION:<br />

The adjusting screw has a min./max. stop. There is danger to damage the governor<br />

when turning by force the adjusting screw so far that it overtravels the specified<br />

control range.<br />

4. Turn screwdriver clockwise to increase the operating voltage and/or anticlockwise to lower the<br />

operating voltage. Adjust voltage range between 14,0 and 14,2 volt (28,0 to 28,4 volt for 24-volt plants).<br />

ATTENTION:<br />

Do not turn adjusting screw so far that it overtravels the stop, to prevent<br />

damages to the governor.<br />

5. After adjustment, remove screwdriver and voltmeter and lock the governor by means of removed plastic<br />

screw.<br />

If voltage cannot be set to specified value, replace governor and/or alternator.<br />

Check of slip pistons:<br />

Disconnect battery and/or main switch.<br />

Unscrew governor. Clean slip ring and wipers; where appropriate, replace wipers.<br />

Z001019/0_6_July 2008 Page ELECTRICAL SYSTEM - 7