96<strong>ACS800</strong>-<strong>04</strong>sizeInputcurr<strong>en</strong>tFuseA A 2 s V Manufacturer Type IEC sizeThree-phase supply voltage 380 V, 400 V, 415 V, 440 V, 460 V, 480 V or 500 V-00<strong>04</strong>-5 4.7 10 483 500 ABB Control OFAF000H10 000-0005-5 5.9 10 483 500 ABB Control OFAF000H10 000-0006-5 7.7 10 483 500 ABB Control OFAF000H10 000-0009-5 10.0 16 993 500 ABB Control OFAF000H16 000-0011-5 12.5 16 993 500 ABB Control OFAF000H16 000-0016-5 17 20 1620 500 ABB Control OFAF000H20 000-0020-5 23 25 3100 500 ABB Control OFAF000H25 000-0025-5 31 40 9140 500 ABB Control OFAF000H40 000-0028-5 36 50 15400 500 ABB Control OFAF000H50 000-0030-5 41 50 15400 500 ABB Control OFAF000H50 000-0<strong>04</strong>0-5 47 63 21300 500 ABB Control OFAF000H63 000-0<strong>04</strong>5-5 54 63 21300 500 ABB Control OFAF000H63 000Three-phase supply voltage 525 V, 550 V, 575 V, 600 V, 660 V or 690 V-0011-7 12 16 1100 690 ABB Control OFAA000GG16 000-0016-7 15 20 2430 690 ABB Control OFAA000GG20 000-0020-7 21 25 4000 690 ABB Control OFAA000GG25 000-0025-7 24 32 7000 690 ABB Control OFAA000GG32 000-0030-7 33 35 11400 690 ABB Control OFAA000GG35 000-0<strong>04</strong>0-7 35 50 22800 690 ABB Control OFAA000GG50 000PDM code:00096931-JFrame sizes R5 and R6Choose betwe<strong>en</strong> gG and aR fuses according to the table under Quick guide forselecting betwe<strong>en</strong> gG and aR fuses on page 100, or verify the operating time bychecking that the short-circuit curr<strong>en</strong>t of the installation is at least the valuegiv<strong>en</strong> in the fuse table. The short-circuit curr<strong>en</strong>t can be calculated as follows:I k2-ph =U2 · R c 2 + (Z k + X c ) 2whereI k2-ph = short-circuit curr<strong>en</strong>t in symmetrical two-phase short-circuit (A)U = network line-to-line voltage (V)R c = cable resistance (ohm)Z k = = z k · U 2 N /S N = transformer impedance (ohm)z k = transformer impedance (%)U N = transformer rated voltage (V)S N = nominal appar<strong>en</strong>t power of the transformer (kVA)X c = cable reactance (ohm).Technical data

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!