89Fan replacem<strong>en</strong>t (R6)To remove the fan, undo the fixing screws. Disconnect the cable. Install the new fanin reverse order.12Bottom view1Additional fanIn <strong>ACS800</strong>-<strong>04</strong>/<strong>U4</strong> (R2...R6) units there is an additional fan in all types except in-0001-2, -0002-2, -0003-2, -0003-3, -00<strong>04</strong>-3, -0005-3, -00<strong>04</strong>-5, -0005-5 and-0006-5.Replacem<strong>en</strong>t (R2, R3)To remove the fan, release the retaining clip (1). Disconnect the cable (2, detachableterminal). Install the new fan in reverse order.12Air flow upwardsRotation directionView from aboveMaint<strong>en</strong>ance