10.07.2015 Views

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

50Prev<strong>en</strong>tion of Unexpected StartThe drive can be equipped with an optional Prev<strong>en</strong>tion of Unexpected Start functionaccording to standards IEC/EN 602<strong>04</strong>-1: 1997; ISO/DIS 14118: 2000 and EN 1037:1996.The Prev<strong>en</strong>tion of Unexpected Start function disables the control voltage of thepower semiconductors, thus prev<strong>en</strong>ting the inverter from g<strong>en</strong>erating the AC voltagerequired to rotate the motor. By using this function, short-time operations (likecleaning) and/or maint<strong>en</strong>ance work on non-electrical parts of the machinery can beperformed without switching off the AC power supply to the drive.The operator activates the Prev<strong>en</strong>tion of Unexpected Start function by op<strong>en</strong>ing aswitch on a control desk. An indicating lamp on the control desk will light, signallingthat the prev<strong>en</strong>tion is active. The switch can be locked out.A Gate Driver Power Supply board (AGPS) and a 3 m connection wire are deliveredwith the Prev<strong>en</strong>tion of Unexpected Start option kit. The Prev<strong>en</strong>tion of UnexpectedStart function complies with EN954-1 categories 1 and 3 wh<strong>en</strong> the followinginstallations are made:The user must install on a control desk near the machinery:• switching/disconnecting device for the circuitry. “Means shall be provided toprev<strong>en</strong>t inadvert<strong>en</strong>t, and/or mistak<strong>en</strong> closure of the disconnecting device.”EN 602<strong>04</strong>-1: 1997.• indicating lamp; on = starting the drive is prev<strong>en</strong>ted, off = drive is operative.• safety relay (type BD5935 has be<strong>en</strong> approved by ABB)(Switching/disconnecting device, indicating lamp and safety relay are not included inthe delivery.)For connections to the drive, see section Prev<strong>en</strong>tion of Unexpected Start, AGPSboard in chapter Electrical installation.WARNING! The Prev<strong>en</strong>tion of Unexpected Start function does not disconnect thevoltage of the main and auxiliary circuits from the drive. Therefore maint<strong>en</strong>ance workon electrical parts of the drive or the motor can only be carried out after isolating thedrive system from the main supply.Note: The Prev<strong>en</strong>tion of Unexpected Start function is not int<strong>en</strong>ded for stopping thedrive. If a running drive is stopped by using the Prev<strong>en</strong>tion of Unexpected Startfunction, the drive will cut off the motor supply voltage and the motor will coast tostop.Planning the electrical installation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!