10.07.2015 Views

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

109AGPS-11CNominal input voltage 115...230 V AC ±10%Nominal input curr<strong>en</strong>t 0.1 A (230 V) / 0.2 A (115 V)Nominal frequ<strong>en</strong>cy50/60 HzMax. external fuse16 AX1 terminal sizes 3 x 2.5 mm 2Output voltage15 V DC ±0.5 VNominal output curr<strong>en</strong>t 0.4 AX2 terminal block type JST B4P-VHAmbi<strong>en</strong>t temperature 0...50 °CRelative humidityMax. 90%, no cond<strong>en</strong>sation allowedDim<strong>en</strong>sions (with <strong>en</strong>closure) 167 x 128 x 52 mm (Height x Width x Depth)Weight (with <strong>en</strong>closure) 0.75 kgApprovalsC-UL, US listedAmbi<strong>en</strong>t conditionsInstallation site altitudeAir temperatureEnvironm<strong>en</strong>tal limits for the drive are giv<strong>en</strong> below. The drive is to be used in a heated,indoor, controlled <strong>en</strong>vironm<strong>en</strong>t.Operationinstalled for stationary use0 to 4000 m (13123 ft) abovesea level [above 1000 m(3281 ft), see sectionDerating]-15 to +50 °C (5 to 122 °F).No frost allowed. See sectionDerating.Storagein the protective package- --40 to +70 °C (-40 to+158 °F)Transportationin the protective package-40 to +70 °C (-40 to+158 °F)Relative humidity 5 to 95% Max. 95% Max. 95%No cond<strong>en</strong>sation allowed. Maximum allowed relative humidity is 60% in the pres<strong>en</strong>ce ofcorrosive gases.Contamination levels(IEC 60721-3-3, IEC 60721-3-2, IEC 60721-3-1)Atmospheric pressureVibration (IEC 60068-2)*No conductive dust allowed.Boards without coating:Chemical gases: Class 3C1Solid particles: Class 3S2Boards with coating:Chemical gases: Class 3C2Solid particles: Class 3S270 to 106 kPa0.7 to 1.05 atmospheresMax. 1 mm (0.<strong>04</strong> in.)(5 to 13.2 Hz),max. 7 m/s 2 (23 ft/s 2 )(13.2 to 100 Hz) sinusoidalBoards without coating:Chemical gases: Class 1C2Solid particles: Class 1S3Boards with coating:Chemical gases: Class 1C2Solid particles: Class 1S370 to 106 kPa0.7 to 1.05 atmospheresMax. 1 mm (0.<strong>04</strong> in.)(5 to 13.2 Hz),max. 7 m/s 2 (23 ft/s 2 )(13.2 to 100 Hz) sinusoidalShock (IEC 60068-2-29) Not allowed Max. 100 m/s 2 (330 ft./s 2 ),11 msFree fall Not allowed 250 mm (10 in.) for weightunder 100 kg (220 lb)100 mm (4 in.) for weightover 100 kg (220 lb)Boards without coating:Chemical gases: Class 2C2Solid particles: Class 2S2Boards with coating:Chemical gases: Class 2C2Solid particles: Class 2S260 to 106 kPa0.6 to 1.05 atmospheresMax. 3.5 mm (0.14 in.)(2 to 9 Hz),max. 15 m/s 2 (49 ft/s 2 )(9 to 200 Hz) sinusoidalMax. 100 m/s 2 (330 ft./s 2 ),11 ms250 mm (10 in.) for weightunder 100 kg (220 lb)100 mm (4 in.) for weightover 100 kg (220 lb)*Note: For frame sizes R2 to R4 with panel option maximum allowed vibration is 3 m/s 2 . For higher vibration use theRPMP kit. See Control Panel Mounting Platform Kit (RPMP) Installation Guide [3AFE64677560 (English)].Technical data

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!