10.07.2015 Views

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

10Perman<strong>en</strong>t magnet motorThese are additional warnings concerning perman<strong>en</strong>t magnet motor drives. Ignoringthe instructions can cause physical injury or death, or damage to the equipm<strong>en</strong>t.Installation and maint<strong>en</strong>ance workWARNING! Do not work on the drive wh<strong>en</strong> the perman<strong>en</strong>t magnet motor is rotating.Also, wh<strong>en</strong> the supply power is switched off and the inverter is stopped, a rotatingperman<strong>en</strong>t magnet motor feeds power to the intermediate circuit of the drive and thesupply connections become live.Before installation and maint<strong>en</strong>ance work on the drive:• Stop the motor.• Ensure that the motor cannot rotate during work. Prev<strong>en</strong>t the start-up of anydrives in the same mechanical group by op<strong>en</strong>ing the “prev<strong>en</strong>tion of unexpectedstart” switch and padlocking it. Make sure that no other system, like hydrauliccrawling drives, are able to rotate the motor directly or through any mechanicalconnection like felt, nip, rope, etc.• Ensure that there is no voltage on the drive power terminals:Alternative 1) Disconnect the motor from the drive with a safety switch or by othermeans. Measure that there is no voltage pres<strong>en</strong>t on the drive input or outputterminals (U1, V1, W1, U2, V2, W2, UDC+, UDC-).Alternative 2) Measure that there is no voltage pres<strong>en</strong>t on the drive input or outputterminals (U1, V1, W1, U2, V2, W2, UDC+, UDC-). Ground the drive outputterminals temporarily by connecting them together as well as to the PE.Alternative 3) If possible, both of the above.Start-up and operationWARNING! Do not run the motor over the rated speed. Motor overspeed leads toovervoltage which may damage or explode the capacitors in the intermediate circuitof the drive.Controlling a perman<strong>en</strong>t magnet motor is only allowed using the <strong>ACS800</strong> Perman<strong>en</strong>tMagnet Synchronous Motor Drive Control Program, or other control programs inscalar control mode.Safety instructions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!