1<strong>04</strong><strong>ACS800</strong>-<strong>U4</strong> size I max Normal use Heavy-duty use FramesizeAir flowHeatdissipationA A HPThree-phase supply voltage 525 V, 575 V or 600 V-0011-7 14 11.5 10 8.5 7.5 R4 61 1050-0016-7 19 15 10 11 10 R4 61 1200-0020-7 28 20 15/20*** 15 15** R4 61 1550-0025-7 38 23 20 20 20** R4 61 1850-0030-7 44 30 25/30*** 25 25** R4 61 2100-0<strong>04</strong>0-7 54 34 30 30 30** R4 61 2400-0050-7 68 46 40 40 40** R5 147 2900-0060-7 84 52 50 42 40 R5 147 3450-0070-7 1<strong>04</strong> 73 60 54 50 R6 238 4200-0100-7 124 86 75 62 60 R6 238 5650-0120-7 172 108 100 86 75 R6 238 6700-0145-7 190 125 125 99 100 R6 238 9100-0175-7 245 155 150 131 125 R6 238 11900-0205-7 245 192 200 147 150 R6 238 14300PDM code: 00096931-J*Overload may be limited to 5% at high speeds (> 90% speed) by the internal power limit of the drive.The limitation also dep<strong>en</strong>ds on motor characteristics and network voltage.**Overload may be limited to 40% at high speeds (> 90% speed) by the internal power limit of thedrive. The limitation also dep<strong>en</strong>ds on motor characteristics and network voltage.*** Higher rating is available with special 4-pole high-effici<strong>en</strong>cy NEMA motor.SymbolsNominal ratingsI max maximum output curr<strong>en</strong>t. Available for 10 s at start, otherwise as long as allowed by drivetemperature.Normal use (10% overload capability)I 2N continuous rms curr<strong>en</strong>t. 10% overload is typically allowed for one minute every 5 minutes.P N typical motor power. The power ratings apply to most 4-pole NEMA rated motors (230 V,460 V or 575 V).Heavy-duty use (50% overload capability)I 2hd continuous rms curr<strong>en</strong>t. 50% overload is typically allowed for one minute every 5 minutes.P hd typical motor power. The power ratings apply to most 4-pole NEMA rated motors (230 V,460 V or 575 V).Note 1: The ratings apply in ambi<strong>en</strong>t temperature of 40°C (1<strong>04</strong>°F). In lower temperatures the ratingsare higher (except I max ).SizingSee page 93.DeratingSee page 94.I 2NP NI 2hdAP hdHP ft 3 /min BTU/HrTechnical data

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!