10.07.2015 Views

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

en/ACS800-04/U4 Hardware Manuals - VAE ProSys sro

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

492) Circuit breakers which have be<strong>en</strong> tested by ABB with the <strong>ACS800</strong> can be used. Fuses must be usedwith other circuit breakers. Contact your local ABB repres<strong>en</strong>tative for approved breaker types andsupply network characteristics.The protective characteristics of circuit breakers dep<strong>en</strong>d on the type, construction and settings of thebreakers. There are also limitations pertaining to the short-circuit capacity of the supply network.WARNING! Due to the inher<strong>en</strong>t operating principle and construction of circuit breakers,indep<strong>en</strong>d<strong>en</strong>t of the manufacturer, hot ionized gases may escape from the breaker<strong>en</strong>closure in case of a short-circuit. To <strong>en</strong>sure safe use, special att<strong>en</strong>tion must be paid tothe installation and placem<strong>en</strong>t of the breakers. Follow the manufacturer’s instructions.Ground fault protectionNote: Circuit breakers must not be used without fuses in the USA.The drive is equipped with an internal ground fault protective function to protect theunit against ground faults in the motor and the motor cable. This is not a personalsafety or a fire protection feature. The ground fault protective function can bedisabled with a parameter, refer to the appropriate <strong>ACS800</strong> Firmware Manual.The EMC filter of the drive includes capacitors connected betwe<strong>en</strong> the main circuitand the frame. These capacitors and long motor cables increase the ground leakagecurr<strong>en</strong>t and may cause fault curr<strong>en</strong>t circuit breakers to function.Emerg<strong>en</strong>cy stop devicesFor safety reasons, install the emerg<strong>en</strong>cy stop devices at each operator controlstation and at other operating stations where emerg<strong>en</strong>cy stop may be needed.Note: Pressing the stop key ( ) on the control panel of the drive does not g<strong>en</strong>eratean emerg<strong>en</strong>cy stop of the motor or separate the drive from dangerous pot<strong>en</strong>tial.Planning the electrical installation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!