11.07.2015 Views

Caroline County, Virginia Request for Proposals Project 25 Radio ...

Caroline County, Virginia Request for Proposals Project 25 Radio ...

Caroline County, Virginia Request for Proposals Project 25 Radio ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

UHF/700 MHz P<strong>25</strong> <strong>Radio</strong> Communications System<strong>Request</strong>ion <strong>for</strong> <strong>Proposals</strong><strong>Caroline</strong> <strong>County</strong>, <strong>Virginia</strong>fiberglass weather hood or awning. The door shall be equipped with ahydraulic door closer.2. The exterior door shall be of aluminum or steel (stainless or galvanized)construction with a finish to match the building finish.3. The door shall withstand the effects of bullets or other projectiles equivalentto a 30.06 high power rifle load fired from a distance of 50 feet with nopenetration to the inner cavity of the door. No interior damage shall besustained including insulation, interior walls, etc.4. The door sill shall be of stepped construction so as to prevent rain waterfrom entering the shelter at the bottom of the door or from around the doorframe. The door frame shall have a weather seal around the door to limit airand water intrusion.H. Finishing:1. The interior and exterior finishes shall be described by the RESPONDENT.Color and finishes shall be selected by the <strong>County</strong> from samples providedby the SELECTED VENDOR or subcontractor.2. All joints shall be sealed with a compressible, resilient sealant.I. AC power system:1. The Contractor shall deliver the building complete with a 200 amperecapacity, 240 volts, single phase electrical panel box with a ground bar.2. This panel shall be equipped with a 200 ampere capacity main circuitbreaker used to supply power <strong>for</strong> all electrical functions related to the site.3. One 200 Amp disconnect switch shall be provided to disconnect utilityservice from the shelter.4. One 200 Amp manual transfer switch shall be provided to switch betweenthe backup generator and generator receptacle.5. One 200 Amp generator receptacle shall be provided – Appleton #AR20044-RS.6. Overall panel size shall be determined by the need to provide the number ofindividual breakers required plus a reserve of at least six 240 Volt slots.7. Breakers <strong>for</strong> shelter air conditioning will be of the bolt-down, not snap-intype.May 27, 2011 Page 53 of 134

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!