11.07.2015 Views

Caroline County, Virginia Request for Proposals Project 25 Radio ...

Caroline County, Virginia Request for Proposals Project 25 Radio ...

Caroline County, Virginia Request for Proposals Project 25 Radio ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

UHF/700 MHz P<strong>25</strong> <strong>Radio</strong> Communications System<strong>Request</strong>ion <strong>for</strong> <strong>Proposals</strong><strong>Caroline</strong> <strong>County</strong>, <strong>Virginia</strong>3. A heavy duty, lead acid 12 VDC battery shall be provided by the generatorset manufacturer. The generator set shall have a frame suitable <strong>for</strong>mounting the battery and include all connecting battery cables.6.4.2 Automatic Transfer Switch (ATS)A. The automatic transfer switch shall be compatible with the generator set so as tomaintain system compatibility and local service responsibility <strong>for</strong> the completeemergency power system.B. Representative production samples of the transfer switch supplied shall havedemonstrated through tests the ability to withstand at least 10,000 mechanicaloperation cycles. One operation cycle is defined as the electrically operatedtransfer from normal to emergency and back to normal.C. Wiring must comply with NEC table 373-6(b). The manufacturer shall furnishschematic and wiring diagrams <strong>for</strong> the particular automatic transfer switch and atypical wiring diagram <strong>for</strong> the entire system.D. Ratings and Per<strong>for</strong>mance:1. The ATS shall be adequately sized to match the generator and shelterelectrical systems.2. The automatic transfer switch shall be a 2-pole design rated <strong>for</strong> 600 VAC200 amps continuous operation in ambient temperatures of -20 degreesFahrenheit (-30 degrees Celsius) to +140 degrees Fahrenheit (+60 degreesCelsius).3. The operating mechanism will be a single operating coil design, electricallyoperated and mechanically held in position.4. A provision will be supplied to allow manual operation of the switch in theevent of logic or electrical coil failure.E. Controls:1. A solid state under-voltage sensor shall monitor all phases of the normalsource and provide adjustable ranges <strong>for</strong> field adjustments <strong>for</strong> specificapplication needs.a. Pick-up and drop-out settings shall be adjustable from a minimum of70% to a maximum of 95% of nominal voltage.May 27, 2011 Page 62 of 134

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!