Net F/T Installation and Operation Manual<br />

Document: 9620-05-net ft-11<br />

Table 18.1—<strong>System</strong> Status Code Bit Assignments<br />

Bit Bit Pattern Description<br />

31 0x80000000 Error bit (set if any error condition exists)<br />

30 0x40000000 CPU or RAM error<br />

29 0x20000000 Digital board error<br />

28 0x10000000 Analog board error<br />

27 0x08000000 Serial link communication error<br />

26 0x04000000 Program memory verification error<br />

25 0x02000000 Halted due to configuration errors<br />

24 0x01000000 Settings validation error<br />

23 0x00800000 Configuration settings incompatible with transducer calibration<br />

22 0x00400000 <strong>Network</strong> communication failure<br />

21 0x00200000 CAN communication error<br />

20 0x00100000 RDT communication error<br />

19 0x00080000 EtherNet/IP protocol failure<br />

18 0x00040000 DeviceNet-compatibility mode protocol failure<br />

17 0x00020000 Transducer Saturation or A/D operation error<br />

16 0x00010000 Threshold latched<br />

15 0x00008000 reserved<br />

14 0x00004000 Watchdog timeout error<br />

13 0x00002000 Stack check error<br />

12 0x00001000 Serial EEPROM I2C communications failure<br />

11 0x00000800 Serial flash SPI communications failure<br />

10 0x00000400 Analog board watchdog timeout error<br />

9 0x00000200 Excessive strain gage excitation current<br />

8 0x00000100 Insufficient strain gage excitation current<br />

7 0x00000080 Artificial analog ground out of range<br />

6 0x00000040 Analog Board power supply too high<br />

5 0x00000020 Analog Board power supply too low<br />

4 0x00000010 Serial link data unavailable<br />

3 0x00000008 Reference voltage or power monitoring error<br />

2 0x00000004 Internal temperature error<br />

1 0x00000002 HTTP protocol failure<br />

0 0x00000001 reserved<br />

– 0x00000000 Healthy<br />