05.12.2015 Views

Network Force/Torque Sensor System

Net F/T Manual - ATI Industrial Automation

Net F/T Manual - ATI Industrial Automation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Net F/T Installation and Operation Manual<br />

Document: 9620-05-net ft-11<br />

4.6 Thresholding Page (moncon.htm)<br />

This page allows you to set up threshold conditions. Threshold conditions compare the transducer<br />

readings to simple user-defined threshold statements. When threshold monitoring is enabled and a<br />

sample is read that satisfies one or more of the active threshold conditions, the user-defined output code<br />

for all threshold conditions satisfied by that sample are bitwise or’ed together to form the threshold<br />

output (in practice, it is very unlikely that more than one threshold sample will be satisfied in a single<br />

sample). The threshold monitoring latch is then set, and threshold monitoring is then paused until a<br />

command to reset the threshold monitoring latch is received. The threshold output is available on the<br />

Snapshot page.<br />

Each threshold condition can be configured for:<br />

• the axis to monitor<br />

• the type of comparison to perform<br />

• the threshold value to use for the comparison<br />

• the output code to send when the comparison is true<br />

Figure 4.6—Thresholding Page<br />

Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />