Net F/T Installation and Operation Manual<br />
Document: 9620-05-net ft-11<br />
4.6 Thresholding Page (moncon.htm)<br />
This page allows you to set up threshold conditions. Threshold conditions compare the transducer<br />
readings to simple user-defined threshold statements. When threshold monitoring is enabled and a<br />
sample is read that satisfies one or more of the active threshold conditions, the user-defined output code<br />
for all threshold conditions satisfied by that sample are bitwise or’ed together to form the threshold<br />
output (in practice, it is very unlikely that more than one threshold sample will be satisfied in a single<br />
sample). The threshold monitoring latch is then set, and threshold monitoring is then paused until a<br />
command to reset the threshold monitoring latch is received. The threshold output is available on the<br />
Snapshot page.<br />
Each threshold condition can be configured for:<br />
• the axis to monitor<br />
• the type of comparison to perform<br />
• the threshold value to use for the comparison<br />
• the output code to send when the comparison is true<br />
Figure 4.6—Thresholding Page<br />