Net F/T Installation and Operation Manual<br />

Document: 9620-05-net ft-11<br />

Figure 3.15—Net Box Cover Screws<br />

The internal electronics have a clear shield to help protect them from debris or errant tool movements.<br />

There are access holes in the shield for the DIP switches and termination resistor jumper.<br />

Figure 3.16—Net Box DIP Switches, Termination Resistor and LEDs<br />

Before replacing the Net Box cover, you must ensure that no debris or liquids are in the chassis. To<br />

replace the Net Box cover, place the cover back on the chassis (verify that the window is above the LEDs<br />

and DIP switches) and tighten the four screws until each is snug.<br />

3.10.1 Termination Resistor<br />

By default, the Net Box ships with a CAN bus termination resistor installed. Remove the<br />

termination jumper if you want to disable the internal termination resistor. To remove the<br />

termination resistor, you will need to use a pair of tweezers or pliers to pull the jumper off.<br />

Safely store the jumper somewhere in case you need to re-enable the termination resistor.<br />

3.10.2 Node Address<br />

By default, the Net Box ships with a CAN Bus base address of 432 and DeviceNet MAC ID of<br />

54. These are defined by the DIP switch settings (see Figure 3.16—DIP Switch Settings for<br />

details).<br />