Net F/T Installation and Operation Manual<br />
Document: 9620-05-net ft-11<br />
Table 8.3—config.cgi Variables<br />
Variable Name Allowed Values Description<br />
cfgusra Text string of up to 16<br />
characters<br />
cfgusrb Text string of up to 16<br />
characters<br />
Stores text in user-defined field #1.<br />
Stores text in user-defined field #2.<br />
8.4 Communications CGI (comm.cgi)<br />
This CGI sets the networking options of the Net Box. Refer to Section 4.8—Communication Settings<br />
Page (comm.htm) for more information on the parameters.<br />
Table 8.4—comm.cgi Variables<br />
Variable Name Allowed Values Description<br />
comnetdhcp Integers: 0 or 1 Sets DHCP behavior.<br />
Value Description<br />
0 Use DHCP if available on network<br />
1 Use software-defined static IP values<br />
comnetip<br />
comnetmsk<br />
comnetgw<br />
Any IPV4 address in dotdecimal<br />
notation<br />
Any IPV4 subnet mask in<br />
dot-decimal notation<br />
Any IPV4 address in dotdecimal<br />
notation<br />
Sets the static IP address to be used when DHCP is<br />
disabled.<br />
Sets the subnet mask to be used when DHCP is<br />
disabled.<br />
Sets the gateway to be used when DHCP is disabled.<br />
comeipe Integers: 0 or 1 Enable (value = 1) or disable (value = 0) EtherNet/IP<br />
protocol. Basic CAN protocol must be selected when<br />
EtherNet/IP protocol is enabled.<br />
comdnte Integers: 0 or 1 Selects CAN bus protocol.<br />
Value Description<br />
0 Basic CAN protocol<br />
1 DeviceNet compatibility-mode protocol<br />
EtherNet/IP protocol must be disabled when DeviceNet<br />
protocol is selected.<br />
comrdte Integers: 0 or 1 Enable (value = 1) or disable (value = 0) RDT interface.<br />
comrdtrate 1 to 7000 Sets the RDT output rate in Hertz. The actual value<br />
used may be rounded up; see Section 4.8–<br />
Communications Settings Page (comm.htm) for details.<br />
comrdtbsiz Integers: 1 to 40 RDT Buffer Mode buffer size.<br />
comrdtmsyn Integers: 0 or 1 Enable (value = 1) or disable (value = 0) multi-unit<br />
synchronization.<br />
comrdtmuid Integers: 0 to 9 Multi-unit synchronization index.<br />