Net F/T Installation and Operation Manual<br />
Document: 9620-05-net ft-11<br />
9.2 Calibration Information (netftcalapi.xml)<br />
The XML page netftcalapi.xml retrieves information about a specific calibration. Retrieved calibration<br />
information has not been modified by any of the Net F/T’s configuration settings.<br />
A calibration index can be specified when requesting this calibration information. This is done by<br />
appending ?index=n to the request, where n is the index of the desired calibration. If a calibration index<br />
is not specified the currently-used calibration will be assumed.<br />
For example, to retrieve calibration information for the third calibration the requested page would be<br />
netftcalapi.xml?index=2.<br />
XML Element Data Type<br />
Table 9.3—XML Elements in netftcalapi.xml<br />
calsn STRING8 Serial number<br />
calpn<br />
caldt<br />
STRING32 Calibration type<br />
STRING20 Calibration date<br />
Calibration Information<br />
calfu USINT <strong>Force</strong> units (refer to config.cgi variable cfgfu for values)<br />
scalfu STRING8 Name of force units<br />
caltu USINT <strong>Torque</strong> units used (refer to config.cgi variable cfgtu for values)<br />
scaltu STRING8 Name of torque units<br />
calmr REAL[6] Calibrated sensing ranges in calfu and caltu units<br />
calcpf DINT Counts per force unit<br />
calcpt DINT Counts per torque unit<br />
calsf DINT[6] Scaling factor for DeviceNet and CAN<br />
calusra STRING16 Calibration note field #1<br />
calusrb STRING16 Calibration note field #2<br />