Net F/T Installation and Operation Manual<br />

Document: 9620-05-net ft-11<br />

8. Common Gateway Interface (CGI)<br />

The Net F/T can be configured over Ethernet using the standard HTTP get method, which sends configuration<br />

variables and their values in the requested URL.<br />

Each variable is only settable from the CGI page which is responsible for that variable. The following tables list<br />

each CGI page and the settable variables associated with it.<br />

URLs are constructed using the syntax:<br />

http:///?<br />

where:<br />

http://<br />

<br />

indicates an HTTP request<br />

is the Ethernet address of the Net F/T system<br />

/ a separator<br />

<br />

the name of the CGI page that holds the variables you will be<br />

accessing<br />

? a separator marking the start of variable assignments<br />

<br />

<br />

a variable assignment using the format described below<br />

a variable assignment using the format described below, but the<br />

variable name is proceeded by an ampersand. This variable<br />

assignment is optional and may be repeated for multiple variables.<br />

Variables are assigned new values using the syntax:<br />

variableName=newValue<br />

where:<br />

variableName<br />

is the name of the variable to be assigned<br />

= indicates assignment<br />

newValue<br />

is the value to be assigned to the variable. Text for text variables<br />

should not be enclosed in quotes. To include the ampersand character<br />

in text for a text variable use %26. Floating point numbers are<br />

limited to twenty characters.<br />

Example:<br />

http://192.168.1.1/setting.cgi?setcfgsel=2&setuserfilter=0&setpke=1<br />

tells the Net F/T at IP address 192.168.1.1 to set CGI variables<br />

setcfgsel to 2, setuserfilter to 0, and setpke to 1.<br />

The maximum length of these URLs may be determined by a number of factors external to the Net F/T.<br />

Exceeding the maximum length may result in an error or variables being incorrectly set.<br />

Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />