Net F/T Installation and Operation Manual<br />
Document: 9620-05-net ft-11<br />
8. Common Gateway Interface (CGI)<br />
The Net F/T can be configured over Ethernet using the standard HTTP get method, which sends configuration<br />
variables and their values in the requested URL.<br />
Each variable is only settable from the CGI page which is responsible for that variable. The following tables list<br />
each CGI page and the settable variables associated with it.<br />
URLs are constructed using the syntax:<br />
http:///?<br />
where:<br />
http://<br />
<br />
indicates an HTTP request<br />
is the Ethernet address of the Net F/T system<br />
/ a separator<br />
<br />
the name of the CGI page that holds the variables you will be<br />
accessing<br />
? a separator marking the start of variable assignments<br />
<br />
<br />
a variable assignment using the format described below<br />
a variable assignment using the format described below, but the<br />
variable name is proceeded by an ampersand. This variable<br />
assignment is optional and may be repeated for multiple variables.<br />
Variables are assigned new values using the syntax:<br />
variableName=newValue<br />
where:<br />
variableName<br />
is the name of the variable to be assigned<br />
= indicates assignment<br />
newValue<br />
is the value to be assigned to the variable. Text for text variables<br />
should not be enclosed in quotes. To include the ampersand character<br />
in text for a text variable use %26. Floating point numbers are<br />
limited to twenty characters.<br />
Example:<br />
http://192.168.1.1/setting.cgi?setcfgsel=2&setuserfilter=0&setpke=1<br />
tells the Net F/T at IP address 192.168.1.1 to set CGI variables<br />
setcfgsel to 2, setuserfilter to 0, and setpke to 1.<br />
The maximum length of these URLs may be determined by a number of factors external to the Net F/T.<br />
Exceeding the maximum length may result in an error or variables being incorrectly set.<br />
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />