Net F/T Installation and Operation Manual<br />

Document: 9620-05-net ft-11<br />

Line 4:<br />

Line 5:<br />

Line 6:<br />

Line 7:<br />

Counts per Unit <strong>Force</strong>. All force values Fx, Fy, Fz in the CSV file must be divided by<br />

this number to get the force values in the selected unit.<br />

<strong>Torque</strong> Units. This is the torque selected on the Configuration page.<br />

Counts per Unit <strong>Torque</strong>. All torque values Tx, Ty, Tz in the CSV file must be<br />

divided by this number to get the torque values in the selected unit.<br />

Header Row. This row names each of the columns of CSV data.<br />

Table 5.1—CSV File Column Headings<br />

Column: A B C D E F G H I J<br />

Name:<br />

Status<br />

(hex)<br />

RDT<br />

Sequence<br />

F/T<br />

Sequence<br />

Fx Fy Fz Tx Ty Tz Time<br />

Column A: Status (hex) is the 32-bit system status code for this row. Each bit signals a certain<br />

diagnostic condition. Normally this code is zero. A non-zero status code normally<br />

means that the Net F/T system needs attention. See Section 18.2—<strong>System</strong> Status Code<br />

for a detailed description of the status code.<br />

Column B: RDT Sequence is a number that starts at one and is incremented with each set of data<br />

that is sent from the Net F/T to the host computer.<br />

Elapsed measurement time can be found with using the formula:<br />

RDT Sequence Number<br />

Elapsed Measurement Time =<br />

RDT Sample Rate<br />

Missing sequences indicate that data packages were lost. To avoid lost samples, see<br />

Section 17.1—Improving Ethernet Throughput.<br />

Column C: F/T Sequence is a number that is incremented with each new F/T measurement. The<br />

Net F/T measures at a constant rate of 7000 samples per second.<br />

Column D: Fx is the Fx axis reading in counts.<br />

Column E:<br />

Column F:<br />

Fy is the Fy axis reading in counts.<br />

Fz is the Fz axis reading in counts.<br />

Column G: Tx is the Tx axis reading in counts.<br />

Column H: Ty is the Ty axis reading in counts.<br />

Column I:<br />

Column J:<br />

Tz is the Tz axis reading in counts.<br />

Time is the time the demo program received the data row from the Net F/T. This time<br />

stamp is created by the computer and is limited to the clock resolution of the computer.<br />