Network Force/Torque Sensor System
Net F/T Manual - ATI Industrial Automation
Net F/T Manual - ATI Industrial Automation
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Net F/T Installation and Operation Manual<br />
Document: 9620-05-net ft-11<br />
Line 4:<br />
Line 5:<br />
Line 6:<br />
Line 7:<br />
Counts per Unit <strong>Force</strong>. All force values Fx, Fy, Fz in the CSV file must be divided by<br />
this number to get the force values in the selected unit.<br />
<strong>Torque</strong> Units. This is the torque selected on the Configuration page.<br />
Counts per Unit <strong>Torque</strong>. All torque values Tx, Ty, Tz in the CSV file must be<br />
divided by this number to get the torque values in the selected unit.<br />
Header Row. This row names each of the columns of CSV data.<br />
Table 5.1—CSV File Column Headings<br />
Column: A B C D E F G H I J<br />
Name:<br />
Status<br />
(hex)<br />
RDT<br />
Sequence<br />
F/T<br />
Sequence<br />
Fx Fy Fz Tx Ty Tz Time<br />
Column A: Status (hex) is the 32-bit system status code for this row. Each bit signals a certain<br />
diagnostic condition. Normally this code is zero. A non-zero status code normally<br />
means that the Net F/T system needs attention. See Section 18.2—<strong>System</strong> Status Code<br />
for a detailed description of the status code.<br />
Column B: RDT Sequence is a number that starts at one and is incremented with each set of data<br />
that is sent from the Net F/T to the host computer.<br />
Elapsed measurement time can be found with using the formula:<br />
RDT Sequence Number<br />
Elapsed Measurement Time =<br />
RDT Sample Rate<br />
Missing sequences indicate that data packages were lost. To avoid lost samples, see<br />
Section 17.1—Improving Ethernet Throughput.<br />
Column C: F/T Sequence is a number that is incremented with each new F/T measurement. The<br />
Net F/T measures at a constant rate of 7000 samples per second.<br />
Column D: Fx is the Fx axis reading in counts.<br />
Column E:<br />
Column F:<br />
Fy is the Fy axis reading in counts.<br />
Fz is the Fz axis reading in counts.<br />
Column G: Tx is the Tx axis reading in counts.<br />
Column H: Ty is the Ty axis reading in counts.<br />
Column I:<br />
Column J:<br />
Tz is the Tz axis reading in counts.<br />
Time is the time the demo program received the data row from the Net F/T. This time<br />
stamp is created by the computer and is limited to the clock resolution of the computer.<br />
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />