Network Force/Torque Sensor System
Net F/T Manual - ATI Industrial Automation
Net F/T Manual - ATI Industrial Automation
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Net F/T Installation and Operation Manual<br />
Document: 9620-05-net ft-11<br />
14.3.8 Thresholding Settings Object (0x73—32 Instances)<br />
Table 14.23—Class Attributes (Instance 0)<br />
Attribute ID Name Data Type Default Data Value Access Rule<br />
1 Revision UINT 1 Get<br />
2 Max Instance UINT 32 Get<br />
3 Number of Instances UINT 32 Get<br />
Table 14.24—Instance Attributes (Instance 1–32)<br />
Attribute ID Name Data Type Default Data Value Access Rule<br />
1 Enable/Disable BOOL N/A Get/Set<br />
2 Axis Number † SINT N/A Get/Set<br />
3 Comparison ‡ SINT N/A Get/Set<br />
4 Counts Value DINT N/A Get/Set<br />
5 Output Code BYTE N/A Get/Set<br />
† Refer to mcxn in Section 7.2—Thresholding CGI (moncon.cgi) for axis information.<br />
‡ Refer to mccn in Section 7.2—Thresholding CGI (moncon.cgi) for comparison information.<br />
Service Codes<br />
Table 14.25—Common Services<br />
Implemented for<br />
Class Level Instance Level<br />
Service Name<br />
0x0E Yes Yes Get_Attribute_Single<br />
0x10 No Yes Set_Attribute_Single<br />
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />