Net F/T Installation and Operation Manual<br />

Document: 9620-05-net ft-11<br />

Table 3.5—Fieldbus Net Box Status LED Descriptions<br />

Status LED<br />

Function<br />

Module<br />

Status<br />

Ethernet<br />

Link Status<br />

Fieldbus<br />

Option<br />

Status<br />

Name<br />

on PCB<br />

MS<br />

EN1<br />

EN2<br />

LED State<br />

Off<br />

Green<br />

Flashing Red<br />

Off<br />

Green<br />

Flashing Green<br />

Off<br />

Green<br />

Flashing Amber<br />

Amber<br />

Description<br />

No power<br />

Correct Operation<br />

Minor fault such as incorrect or inconsistent configuration<br />

No Ethernet link (or no power)<br />

Ethernet link established<br />

Ethernet activity<br />

Fieldbus disabled (or no power)<br />

Fieldbus connected<br />

Fieldbus activity<br />

The NS/BF LED displays only the status of the highest priority bus connected. The<br />

priorities are as follows, in order of highest to lowest: Fieldbus, EtherNet/IP, DeviceNet.<br />

Off<br />

Bus<br />

Fieldbus<br />

EtherNet/IP<br />

DeviceNet<br />

Description<br />

No IP address assigned or network disabled (or<br />

no power)<br />

Pending duplicate MAC ID test or network<br />

disabled (or no power)<br />

<strong>Network</strong><br />

Status/Bus<br />

Failure<br />

NS/BF<br />

Green<br />

Flashing Green<br />

Bus<br />

Fieldbus<br />

EtherNet/IP<br />

DeviceNet<br />

Bus<br />

Fieldbus<br />

EtherNet/IP<br />

DeviceNet<br />

Description<br />

<strong>Network</strong> connected<br />

DeviceNet master connected<br />

Description<br />

IP address assigned without connecting to<br />

network<br />

No connection to network<br />

Flashing Red<br />

Connection(s) timed out<br />

Red<br />

Bus<br />

Fieldbus<br />

EtherNet/IP<br />

DeviceNet<br />

Description<br />

Duplicate IP address found<br />

Duplicate IP address found or EtherNet/IP<br />

network<br />

<strong>Network</strong> error<br />

Transducer<br />

Saturation<br />

Sat<br />

Off<br />

Red<br />

Transducer load is appropriate (or no power)<br />

Transducer has too much load and is saturated. This causes system<br />

load outputs to be invalid<br />

Transducer<br />

Link Status<br />

Xdcr<br />

Green<br />

Red<br />

Data acquisition system functioning properly<br />

Data acquisition system error or power-up sequence is being<br />

executed<br />

Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />