Network Force/Torque Sensor System
Net F/T Manual - ATI Industrial Automation
Net F/T Manual - ATI Industrial Automation
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Net F/T Installation and Operation Manual<br />
Document: 9620-05-net ft-11<br />
Table 3.5—Fieldbus Net Box Status LED Descriptions<br />
Status LED<br />
Function<br />
Module<br />
Status<br />
Ethernet<br />
Link Status<br />
Fieldbus<br />
Option<br />
Status<br />
Name<br />
on PCB<br />
MS<br />
EN1<br />
EN2<br />
LED State<br />
Off<br />
Green<br />
Flashing Red<br />
Off<br />
Green<br />
Flashing Green<br />
Off<br />
Green<br />
Flashing Amber<br />
Amber<br />
Description<br />
No power<br />
Correct Operation<br />
Minor fault such as incorrect or inconsistent configuration<br />
No Ethernet link (or no power)<br />
Ethernet link established<br />
Ethernet activity<br />
Fieldbus disabled (or no power)<br />
Fieldbus connected<br />
Fieldbus activity<br />
The NS/BF LED displays only the status of the highest priority bus connected. The<br />
priorities are as follows, in order of highest to lowest: Fieldbus, EtherNet/IP, DeviceNet.<br />
Off<br />
Bus<br />
Fieldbus<br />
EtherNet/IP<br />
DeviceNet<br />
Description<br />
No IP address assigned or network disabled (or<br />
no power)<br />
Pending duplicate MAC ID test or network<br />
disabled (or no power)<br />
<strong>Network</strong><br />
Status/Bus<br />
Failure<br />
NS/BF<br />
Green<br />
Flashing Green<br />
Bus<br />
Fieldbus<br />
EtherNet/IP<br />
DeviceNet<br />
Bus<br />
Fieldbus<br />
EtherNet/IP<br />
DeviceNet<br />
Description<br />
<strong>Network</strong> connected<br />
DeviceNet master connected<br />
Description<br />
IP address assigned without connecting to<br />
network<br />
No connection to network<br />
Flashing Red<br />
Connection(s) timed out<br />
Red<br />
Bus<br />
Fieldbus<br />
EtherNet/IP<br />
DeviceNet<br />
Description<br />
Duplicate IP address found<br />
Duplicate IP address found or EtherNet/IP<br />
network<br />
<strong>Network</strong> error<br />
Transducer<br />
Saturation<br />
Sat<br />
Off<br />
Red<br />
Transducer load is appropriate (or no power)<br />
Transducer has too much load and is saturated. This causes system<br />
load outputs to be invalid<br />
Transducer<br />
Link Status<br />
Xdcr<br />
Green<br />
Red<br />
Data acquisition system functioning properly<br />
Data acquisition system error or power-up sequence is being<br />
executed<br />
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />