Net F/T Installation and Operation Manual<br />
Document: 9620-05-net ft-11<br />
There is no output data if the Ethernet/IP O2T Data option on the Communications page (Section 4.8) is<br />
disabled.<br />
Table 14.3—Ethernet/IP Output Mapping<br />
Byte Bit Name Description/Function<br />
0 Bias Perform tare function to zero out any load reading<br />
1 Reset Latch Reset threshold latch<br />
2 reserved<br />
3 reserved<br />
0<br />
4 reserved<br />
5 reserved<br />
6 reserved<br />
7 reserved<br />
0 Config Select bit 0<br />
1 Config Select bit 1<br />
Selects a Net F/T configuration, from 0 to 15<br />
2 Config Select bit 2<br />
3 Config Select bit 3<br />
1<br />
4 reserved<br />
5 reserved<br />
6 reserved<br />
7 reserved<br />
2 0-7 Threshold high Threshold enable mask, high byte<br />
3 0-7 Threshold low Threshold enable mask, low byte<br />