Net F/T Installation and Operation Manual<br />
Document: 9620-05-net ft-11<br />
12. EtherNet/IP Operation<br />
12.1 Overview<br />
The Net F/T operates as a Server on the EtherNet/IP network. It supports Class 3 Connected Explicit<br />
Messaging. UCMM Explicit Messaging, and Class 1 Connected Cyclic I/O Messaging. It supports one<br />
input-only connection and does not support a listen-only connection. The Net F/T does not support any<br />
Client functionality.<br />
EtherNet/IP uses the CIP protocol described in Section 12—EtherNet/IP and DeviceNet CIP Model.<br />
EtherNet/IP Protocol must be enabled on the Communications page to use EtherNet/IP.<br />
Table 12.1—Class 1 Connection Information Parameters<br />
Instance Size (bytes) RT Transfer Format Connection Type<br />
Configuration 128 0 n/a n/a<br />
Input (Target to Originator) 100 28 Modeless Point-to-Point<br />
Output (Originator to Target)<br />
Ethernet/IP O2T Data<br />
Disabled<br />
Output (Originator to Target)<br />
Ethernet/IP O2T Data<br />
Disabled<br />
102 0 Modeless Point-to-Point<br />
102 4 Run/Idle Point-to-Point<br />
12.2 Module and <strong>Network</strong> Status LED<br />
The module status LED is identified on the Net Box as MS. It provides device status for power and<br />
proper operation. The EtherNet/IP network status LED is identified on the Net Box as NS EN. Refer to<br />
Figure 3.17—Status LEDs and Table 3.4—Standard Net Box Status LED Descriptions for an outline of<br />
the LED operation.<br />
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />