Net F/T Installation and Operation Manual<br />

Document: 9620-05-net ft-11<br />

Units:<br />

Output Code:<br />

Reset Latch button:<br />

Displays the counts value in the units of the active configuration. This value is<br />

only updated after the Apply button is clicked.<br />

When this statement’s comparison is found true, this 8-bit value will be<br />

bitwise or’ed with the Output Code values of all other true statements to form<br />

the threshold output. Any set bits remain latched until Reset Latch is called. If<br />

no statements have been true the threshold output will be zero.<br />

The value is displayed in hexadecimal in the format 0x00. Output codes may<br />

be entered in the hexadecimal format or they may be entered in decimal.<br />

Clears any threshold latching and reloads the Thresholding page. If no<br />

threshold conditions remain true then Thresholds Breached, Thresholds<br />

Output, and Threshold Latched will all be set to zero and the <strong>System</strong> Status:<br />

Threshold Level Latched condition will be cleared.<br />

4.6.1 Threshold Relay<br />

The threshold relay closes its contacts when Threshold Latched is true. This allows external<br />

electrical equipment to react when this occurs. Possible uses include control of E-stop circuits.<br />

Relay operation is determined by the Relay Trigger, Relay Behavior, and Relay Momentary<br />

Minimum-On Time settings.<br />

For increased reliability, it is best to monitor both the normally open (NO) and normally closed<br />

(NC) relay contacts. This allows detection of some cabling or relay issues.<br />

The threshold relay contacts (NC, NO, and COM) are protected against overload by a<br />

resettable fuse, see Section 19.3.4—Standard Threshold Relay for electrical specifications.<br />

4.6.1.1 Standard Net Box Threshold Relay<br />

The standard Net Box threshold relay is a mechanical relay. (The fieldbus Net Box<br />

has the solid-state relay described in Section 4.6.1.2—Fieldbus Net Box and<br />

Optional Solid State Threshold Relay).<br />

Figure 4.7—Standard Net Box Threshold Relay Connector Pin Assignment (Male-pin side view)<br />

Table 4.4—Solid-State Relay Connector Pin Descriptions<br />

Pin Name Description<br />

1 NO Normally open connection<br />

3 NC Normally closed connection<br />

4 Com Common<br />

CAUTION: The solid-state relay connections are polarity<br />

dependent. A reverse-polarity connection could cause high<br />

current flow and damage the Net Box or user equipment.<br />

Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />