05.12.2015 Views

Network Force/Torque Sensor System

Net F/T Manual - ATI Industrial Automation

Net F/T Manual - ATI Industrial Automation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Net F/T Installation and Operation Manual<br />

Document: 9620-05-net ft-11<br />

Vssr vs. Issr<br />

5V<br />

Vssr (voltage drop)<br />

4V<br />

3V<br />

2V<br />

1V<br />

0V<br />

0mA 10mA 20mA 30mA 40mA<br />

19.3.6 NetBox Transducer Cabling<br />

Issr (current)<br />

Normally the NetBox is connected to the Transducer via an industry-standard DeviceNet<br />

cordset. In cases where this type of cordset cannot be used, the following must be observed:<br />

- Cable specifications for DeviceNet Thick Cabling are ideal.<br />

- The RS485+ and RS485- lines must form a twisted pair.<br />

- The cable capacities should be low enough to work with 1.25 Mbps.<br />

- The total resistance of each conductor should be no more than 0.5Ω.<br />

Figure 19.4—Netbox’s Transducer Cable Connector (female Pins)<br />

Figure 19.5—Transducer’s Transducer Cable Connector (male pins)<br />

19.4 Net Box Weight<br />

Table 19.6—Net Box Weight<br />

Condition<br />

Weight<br />

Without Mounting Plate 0.8 kg (1.8 lbs)<br />

With Mounting Plate 1.1 kg (2.4 lbs)<br />

Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: +1.919.772.0115 • Fax: +1.919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />